Ucc3912 Integrated Electronic Circuit Breaker Ic for Hot-swap and Power Management Applications

ثبت نشده
چکیده

Today’s design engineers are faced with a variety of choices when selecting protection devices to meet their circuit or system’s design requirements. Fuses, positive temperature coefficient (PTC) resistors, and electromechanical circuit breakers represent only a sampling of the technologies available to meet their needs. Each of these devices provides a different degree of security, ranging from simple short circuit protection to devices which offer active current limiting and remotely resettable operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated Preventive and Predictive Maintenance Markov Model for Circuit Breakers Equipped With Condition Monitoring

The Circuit Breaker (CB) is one of the most important equipment in power systems. CB must operate reliably to protect power systems as well as to perform tasks such as load disconnection, normal interruption, and fault current interruption. Therefore, the reliable operation of CB can affect the security and stability of power network. In this paper, effects of Condition Monitoring (CM) of CB on...

متن کامل

An Innovative System for Full-Management of CB Using Current Injection Method

In this article, an innovative supervision system will be proposed that can observe and analyze health of Circuit Breaker’s trip coil. The proposed design also logs changes in the coil's quality and informs network supervisor in case of Circuit Breaker (CB) failure. This system injects small direct currents to the Circuit Breaker connections and the trip coil to compute CB’s health and characte...

متن کامل

Droplet-based Hot Spot Cooling Using Topless Digital Microfluidics on a Printed Circuit Board

Thermal management is a critical issue in integrated circuit (IC) design. With each new IC technology generation, feature sizes decrease, operating speeds increase, and package densities increase, contributing to larger power consumption and elevated die temperatures. Higher temperatures are detrimental to circuit behavior and reliability. Furthermore, hot spots due to spatially non-uniform hea...

متن کامل

Bi-directional power management and fault tolerant feature in a 5-kW multilevel dc–dc converter with modular architecture

A 5-kW multilevel modular capacitor-clamped dc–dc converter (MMCCC) with bi-directional power management and real-time fault bypassing capability will be presented in this study. The modular structure of the MMCCC topology was utilised to build this 5-kW converter with necessary redundancy and hot swap feature for industrial and automotive applications including a future plug-in hybrid or fuel-...

متن کامل

Design on the HCB based on IGCT and Neural Network Current Detection

Nowaday, the traditional circuit breaker is which action slow, poor reliability, can not meet large grid interconnection and flexible AC transmission requirements. To address those shortcomings of traditional circuit breaker, an idear is put forward that traditional mechanical circuit breaker combinates of power electronic switch-IGCT to build a new type of hybrid circuit breaker device (Hybrid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997