A clinical experience of ‘STAMP’ plate-guided Bonebridge implantation

نویسندگان

  • Yutaka Takumi
  • Nozomu Matsumoto
  • Byunghyun Cho
  • Hidenori Ono
  • Kentaro Mori
  • Keita Tsukada
  • Aya Ichinose
  • Hidekane Yoshimura
  • Satoshi Iwasaki
  • Shizuo Komune
  • Shin-ichi Usami
چکیده

CONCLUSION The surface template-assisted marker positioning (STAMP) method is useful for successful Bonebridge™ (BB) implantation on a planned site while avoiding dangerous positions. OBJECTIVES To confirm the usefulness of the STAMP method for the safe operation of BB. METHODS From a patient's temporal bone CT data, a guide plate and confirmation plate were generated by the STAMP method. The guide plate is used to mark the correct place for implantation, while the confirmation plate lets us know the correct angle and depth of the hole. RESULTS With the guide plate, the correct place for BB implantation was easily found. The hole was made to be an appropriate size with the confirmation plate while exposing only a small part of sigmoid sinus as simulated. Finally, the BB implant was successfully placed exactly at the planned site.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image-guided implantation of the Bonebridge™ with a surgical navigation: A feasibility study

OBJECTIVE To access a method of fitting a designated location on the patient's temporal bone by surgically navigating to the Bonebridge implantation. STUDY DESIGN A patient with unilateral profound hearing loss received early intervention with the Bonebridge implant for binaural hearing. The optimal implant site was determined from computed tomography (CT) images using a three-dimensional (3D...

متن کامل

Bonebridge Implantation for Conductive Hearing Loss in a Patient with Oval Window Atresia.

The occurrence of oval window atresia is a rare anomaly with conductive hearing loss. Traditional atresia surgeries involve challenging surgical techniques with risks of irreversible inner ear damage. Recent reports on Bonebridge (Medel, Innsbruck, Austria), a novel implantable bone conduction hearing aid system, assert that the device is safe and effective for conductive hearing loss. We prese...

متن کامل

Experience plus explanation

The more clearly the clinician comprehends the processes of clinical perception and of linking the experience with explanation, the more thoughtfully clinical students can be guided to construct an accurate 'clinical memory' of cases, and to construct a sound 'working knowledge' structure from their personal 'examined experience'. The structuring of the steps of clinical learning is intended as...

متن کامل

Frequency Aanalysis of Annular Plates Having a Small Core and Guided Edges at Both Inner and Outer Boundaries

This paper deals with frequency analysis of annular plates having a small core and guided edges at both inner and outer boundaries. Using classical plate theory the governing differential equation of motion for the annular plate having a small core is derived and solved for the case of plate being guided at inner and outer edge boundaries. The fundamental frequencies for the first six modes of ...

متن کامل

Guided bone regeneration: A literature review

Guided bone regeneration (GBR) is a reconstructive procedure of alveolar ridge using membranes. This procedure is indicated when there is no sufficient bone for implantation, or in the case of optimal implant installation for esthetic or functional needs. GBR can be performed before implant placement, when there is not enough bone for initial stability of implants and less predictable outcomes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 134  شماره 

صفحات  -

تاریخ انتشار 2014