"Metal-on-metal total hip replacement. What does the literature say?".
نویسندگان
چکیده
Second-generation metal-on-metal (M/M) total hip replacements were introduced into clinical use in the late 1980s and demonstrate equivalent survivorship to conventional metal-on-polyethylene prostheses. Wear rates are comparable to those of first-generation designs that survived for a long time in the body. Biological effects from metal ions remain a concern. Patients with both first- and second-generation M/M hips have higher levels of cobalt and chromium in their blood and urine than either patients with metal-on-polyethylene devices or unoperated patients. Concerns include the potential for acquired hypersensitivity, mutagenicity, and carcinogenicity. However, reports of proven adverse effects are scant. Prospective, randomized trials with follow-up in excess of 15 years will be needed to differentiate between the performance and effects of M/M and other bearing combinations. Key words: totalhip arthroplasty, metal-on-metal, wear, biological effects, clinical results.
منابع مشابه
Important Topics on Contemporary Total knee Arthroplasty: what Does Recent Literature Say?
In this Editorial I want to comment on eight recent articles that can help us to better understand still controversial matters related to total knee arthroplasty (TKA). In this Editorial I want to comment on eight recent articles that can help us to better understand still controversial matters related to total knee arthroplasty (TKA).
متن کاملIon Release from Metal-on-metal Hip Resurfacing Implants Does Not Differ from Standard Metal-on-metal Total Hip Replacement
STANDARD METAL-ON-METAL TOTAL HIP REPLACEMENT *Moroni A, **Savarino L, *Cadossi M, **Greco M, **Baldini N, *Giannini S * Rizzoli Orthopaedic Institute, Bologna, Italy **Laboratory for Pathophysiology of Orthopaedic Implants, Rizzoli Orthopaedic Institute, Bologna, Italy [email protected] INTRODUCTION Modern metal-on-metal (MOM) hip resurfacing has been introduced as a less invasive method of join...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملMortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics
OBJECTIVES To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. DESIGN Retrospective cohort study. SETTING English hospital episode statistics database linked to mortality records from the Office for National Statistics. POPULATION All adults who underwent primary elective hip replacement for osteoarthritis from ...
متن کاملThe clinical performance of metal-on-metal as an articulation surface in total hip replacement.
The metal-on-metal articulations in total hip arthroplasty (THA) were widely used between 1960 and 1975. The McKee-Farrar and other first-generation prostheses failed at a high rate because impingement caused early component loosening. The problem of early component loosening was corrected by improved component design and better manufacturing quality. Second-generation metal-on-metal total hip ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 20 6 شماره
صفحات -
تاریخ انتشار 2005