U-Tube Manometer Calibration using ANFIS
نویسنده
چکیده
This paper deals with the implementation of the Adaptive neuro fuzzy inference system (ANFIS) on a Xilinx based Field Programmable Gate Array Spartan-3E. The implemented hardware is then used to efficiently calibrate the U-Tube manometer, in which the relation between the level of mercury and the Capacitance developed across the Copper Plates of the manometer is highly non-linear. This system shows that the ANFIS can be implemented in hardware and can be used to calibrate the non-linear systems effectively. General Terms Calibration, Artificial intelligence, Real time applications of artificial intelligence, ANFIS, Training algorithms for ANFIS, sigmoid function, Floating Point Arithmetic Unit
منابع مشابه
Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer
This paper presents comparative study of a new type of manometer calledconcentric tube bulb (C.T.B) manometer. Its performance of measuring differential heightis studied against conventional U-shaped manometer. Pressure drops and mass flow ratesare calculated by taking various systems comprising of different flow measuring devicessuch as orifice and venturimeters using both U- shaped and C.T.B ...
متن کاملتخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر
Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...
متن کاملPressure Drop in Liquid-Solid Circulating Fluidized Beds
An experiment was conducted to obtain data of pressure drop in riser tubes of liquid-solid circulating fluidized beds. In the experiment, 2 kinds of riser tube having a diameter of 24mm and 36mm were used. Tested particles were of glass and ceramics, and their diameter range was from 2.10 to 4.95mm. Water at ambient conditions was used as the fluidizing fluid. Pressure drop in riser tubes was m...
متن کاملA modified method for the calibration of warburg flasks and manometers.
During the last few years several methods have been described for the calibration of W a r b u r g flasks and manomete r s wi th mercury1, ~ ,8. Al though in all these methods the calibration is carried out in two steps, so t ha t it can easily be performed by one operator, they have the disadvantage, in our view, t ha t the flasks m u s t always be filled wi th so much mercury t ha t it exact ...
متن کاملHandcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure
OBJECTIVE To test the agreement between two handcrafted devices and a cuff-specific manometer. METHODS The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1...
متن کامل