In vitro retention force measurement for three different attachment systems for implant-retained overdenture

نویسندگان

  • Kareem Mohammed Reda
  • Ibrahim Ramadan El-Torky
  • Mohamed Nabeel EL-Gendy
چکیده

AIM The aim of this study is to compare the retention force of three different types of overdenture attachment systems used in implant-retained mandibular complete overdentures. MATERIALS AND METHODS Twenty-one similar acrylic resin blocks were prepared and divided into three study groups: Group A (snap attachment) - 10 specimens, Group B (locator attachment) - 1 specimen, and Group C (syncone attachment) - 10 specimens. A single rectangular heat cure acrylic resin block with two implant analogs 22 mm apart was used with all specimens. Each specimen was subjected to 5500 cycles of insertion and removal in the presence of artificial saliva, representing 5 years of usage. Retention was measured three times for each specimen using universal testing machine. Data were analyzed using one-way and two-way analysis of variance at 95% level of confidence. RESULTS Locator attachment group (Group B) showed the greatest retention level throughout the study, followed by snap attachment (Group A), and syncone attachment (Group C) showed the lowest retention level. CONCLUSION Regardless of the initial retention level of overdenture attachment, gradual loss of retention values is inevitable. However, the rate of retention loss in overdenture attachments is higher in types which comprised plastic parts within their components, rather than those totally made up of noble metals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

AIM The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles. METHODOLOGY Edentulous mandibular models were made with heat-cured polymethyl methacrylate resin. Two implant replicas (CMI), of 3.75 mm diameter and 10 mm length, were placed in the intraforaminal region. Acrylic res...

متن کامل

Comparison of retention and stability of two implant-retained overdentures based on implant location.

STATEMENT OF PROBLEM The location of dental implants and the choice of retentive attachments for implant-retained overdentures are selected based on clinician preference, expert opinion, or empirical information. Limited information is available regarding implant position and the effect on the retention and stability of 2-implant mandibular implant overdentures. PURPOSE The purpose of this in...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

PURPOSE The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in o...

متن کامل

Comparison of stress distribution around implants with two different attachments in overdenture supported by four maxillary implants (FEA method)

As a general rule, the purpose of treatment planning should be minimization and evenly distribution of mechanical stress in the adjacent implant and bone system. Various experimental studies have examined the distribution of stress in the implant supporting bones, thus avoiding the dangers involved. But there is still controversy about biomechanical effects and stress distribution in different ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016