Temperature Change When Drilling Near the Distal Femoral Physis in a Skeletally Immature Ovine Model.

نویسندگان

  • Allison M Tenfelde
  • Amanda O Esquivel
  • Allison M Cracchiolo
  • Stephen E Lemos
چکیده

BACKGROUND The possibility of physeal injury during anterior cruciate ligament reconstruction in the pediatric population is a concern. The purpose of this study was to determine whether drilling at or near the physis could cause a temperature increase that could trigger chondrolysis. METHODS Skeletally immature cadaveric lamb distal femurs were used for this study and randomly placed in 1 of 6 groups (n=10 in each group). We examined the 8 and 10 mm Flipcutter at a distance of 0.5 mm from the physis and an 8 and 10 mm acorn-tipped reamer at a distance of 0.5 and 3.0 mm from the physis. During drilling, temperature change at the distal femoral physis was continuously measured until the temperature decreased to the original value. RESULTS An interreamer comparison yielded a significant difference when drilling 0.5 mm from the physis (P=0.001). Pair-wise Mann-Whitney post hoc tests were performed to further evaluate the differences among the groups. The 8 mm FlipCutter had a significantly higher maximum temperature (39.8±1.4°C) compared with the 10 mm FlipCutter (38.0±0.6°C, P=0.001), 8 mm acorn-tipped reamer (38.1±0.9°C, P=0.007), and 10 mm acorn-tipped reamer (37.5±0.3°C, P<0.001). CONCLUSIONS The risk of thermal-induced injury to the physis is low with an all epiphyseal drilling technique, when a traditional acorn-tipped reamer over a guidepin is utilized, even if the drilling occurs very close to the physis. In addition, the risk of drilling with a FlipCutter is low, but may be greater than a traditional reamer. CLINICAL RELEVANCE Thermal-induced necrosis is a realistic concern, due to the characteristics of the distal femoral physis, and the propensity for this physis to respond poorly to injury. Our study supports that drilling near the physis can be done safely, although smaller reamers and nontraditional designs may generate higher heat. LEVEL OF EVIDENCE Level I-basic science.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transphyseal ACL Reconstruction in Skeletally Immature Patients

BACKGROUND Most studies examining the safety and efficacy of transphyseal anterior cruciate ligament (ACL) reconstruction for skeletally immature patients utilize transtibial drilling. Independent femoral tunnel drilling may impart a different pattern of distal femoral physeal involvement. PURPOSE To radiographically assess differences in distal femoral physeal disruption between transtibial ...

متن کامل

Anatomic landmarks utilized for physeal-sparing, anatomic anterior cruciate ligament reconstruction: an MRI-based study.

BACKGROUND Anterior cruciate ligament (ACL) injury and reconstruction in the skeletally immature patient are becoming more common. The purpose of this study was to develop a reproducible anatomic ACL reconstruction technique, based on intra-articular and extra-articular landmarks, that reliably produces a femoral tunnel of adequate length and diameter while avoiding the distal femoral physis. ...

متن کامل

Physeal Disruption During ACL Reconstruction in Skeletally Immature Patients

This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...

متن کامل

A Magnetic Resonance Imaging Study of the Significance of the Distal Femoral Physis During Medial Patellofemoral Ligament Reconstruction

BACKGROUND Medial patellofemoral ligament (MPFL) reconstruction in adults often utilizes screw fixation in the distal femur. The aim was to define the safety of similar fixation in young patients, with respect to their open physis. PURPOSE To define the age-related relationship between the femoral insertion of the MPFL and the medial aspect of the distal femoral physis on magnetic resonance i...

متن کامل

Physeal-sparing tibial eminence fracture fixation with a headless compression screw.

Displaced tibial intercondylar eminence fractures frequently require operative fixation. Surgical techniques for fixation include the use of headed screws or sutures. However, these fractures commonly occur in skeletally immature patients, and current techniques violate the proximal tibial physis to maintain reduction and can result in growth disturbances. The authors present a physeal-sparing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 36 7  شماره 

صفحات  -

تاریخ انتشار 2016