- Fastscan - a Computerized, Anthropometrically Designed, High Throughput, Whole Body Counter for the Nuclear Industry

نویسندگان

  • F. L. Bronson
  • L. F. Booth
  • D. C. Richards
چکیده

In the past ten years, the use of whole body counters in nuclear power plants has grown significantly. The average counting load is now 2000 5000 counts per year at a typical multi-unit station. This paper reports the results of our evaluation as to the desirable characteristics of a whole body counting system and the performance of the FASTSCAN counter. FASTSCAN is a linear geometry counter, designed to accurately measure inhaled or ingested radioactivity in subjects covering 99% of the size range of the working population (both male and female). Its sensitivity is such that a typical MDL is less than 5 nCi of Cs-137 or Co-60 in a one-minute count. There are no moving parts to break or slow down the subject's entrance and exit. The software performs complete nuclide identification and quantification. It uses peak searching and detection techniques to allow for the identification and calculation of unexpected nuclides and to allow the user to quickly perform his own efficiency calibrations. The operator interacts with a menu-driven program, which is easy to understand by a technician, but flexible enough to allow a wide variety of special procedures by the sophisticated user. The program is also designed to allow it to be easily modified for customer-specific data collection formats and report generation formats. DESIGN PHILOSOPHY OF THE FASTSCAN

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detecting residual fluorine 18 from a medical PET-CT procedure during population whole body counter screening in Fukushima.

After the Fukushima Daiichi nuclear incident in 2011, radiation contamination of the affected area raised public health concerns about internal radiation exposure. Internal radiation exposure screening using a whole body counter (WBC) (Fastscan Model 2251, Canberra Inc, Meriden, CT) has been performed for the affected residents in Soma City, 40 km north of the Fukushima Daiichi nuclear power pl...

متن کامل

Unusual false-positive results of whole-body 131I scintigraphy: Four different case scenarios

Post-treatment or diagnostic whole-body radioiodine scintigraphy is widely used to assess the residual, recurrence, or metastases of differentiated thyroid carcinoma because of the high sensitivity and accuracy that this assessment provides. While bearing in mind all the diagnostic potential of this test, we have to consider its’ potential pitfalls, as well. Herein, we present 4 patients with d...

متن کامل

Measurement of Strontium-90 in the Persian Gulf Fish by Extraction Chromatography with Sr-resin and Liquid Scintillation Counter

Background: Despite its beneficial effects on human life, the nuclear industry has its own risks. Strontium 90 (90Sr) is one of the most dangerous radionuclides produced by the uranium 235 fission, and replaces the bone calcium in the human body, which causes cancer. Ensuring the safety of nuclear facilities to protect employees, people and the environment is among the main goals of nuclear saf...

متن کامل

Whole body phantoms for the determination of dosimetry parameters needs for patients in nuclear medicine [Persian]

This study aims to give data concrning phantom material made in Iran i'rom a natural rubber which is used for obtaining calibration data for patient dose measurements in nuclear medicine applications of radionuclides for therapy and diagnosis. Is showed to be a tissue equivalent material cheap (25000 Rials the material itself and 35000 Rials the process of casting and moulding etc.), easi...

متن کامل

Comparison of 99mTc-MDP and 99mTc-MIBI whole body scans for diagnosis of widespread skeletal metastases [Persian]

Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient’s life, both quantitatively and qualitatively, and prevent exacerbation of the disease and disabling complications. In this study, 22 patients with est...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998