Comparison of high resolution gradient echo, XBONE T1, XBONE T2, Spin Echo T1 and 3D SST1 magnetic resonance imaging sequences for imagining the canine elbow.
نویسندگان
چکیده
Twenty canine elbows were examined by low-field MRI. The objective of this study was to compare five magnetic resonance sequences: High Resolution Gradient Echo in the sagittal plane, XBONE T2 in the sagittal plane, Spin Echo T1 in the sagittal plane, Spin Echo T1 in the dorsal plane and 3D SST1 and XBONE T1 in the transverse plane, and to determine which sequences have the highest diagnostic value in imagining the canine elbow. High Resolution Gradient Echo, XBONE T2 and Spin Echo T1 sequences in the sagittal plane proved to be very useful in evaluations of osseous structures such as the medial coronoid process, the anconeal process of the ulna and joint surfaces. The above sequences facilitate evaluations of radial extensor muscle of the wrist, biceps brachii muscle, triceps brachii muscle and the flexor carpi ulnaris muscle. 3D SST1 and XBONE T1 sequences in the transverse plane produce high-quality images of the medial humeral condyle and surfaces of the elbow joint. Those sequences are also useful for evaluating the surrounding muscles: extensor digitorum communis muscle, extensor carpi radialis muscle, deltoid muscle, biceps brachii muscle, pronator teres muscle and flexor carpi ulnaris muscle. The Spin Echo T1 sequence in the dorsal plane facilitates assessments of joint surfaces, medial humeral condyle, superficial digital flexor muscle, deep digital flexor muscle, triceps brachii muscle and extensor digitorum lateralis muscle. The Spin Echo T1 sequence in the sagittal plane has a short scan time, but it produces images of lower quality than High Resolution Gradient Echo and XBONE T2 sequences in the sagittal plane.
منابع مشابه
Most commonly used sequences and clinical protocols for brain and spine magnetic resonance imaging allowing better identification of pathological changes in dogs.
Magnetic resonance imaging is the best imaging modality for the brain and spine. Quality of the received images depends on many technical factors. The most significant factors are: positioning the patient, proper coil selection, selection of appropriate sequences and image planes. The present contrast between different tissues provides an opportunity to diagnose various lesions. In many clinics...
متن کاملLateral ulnar collateral ligament of the elbow: optimization of evaluation with two-dimensional MR imaging.
PURPOSE To compare, in a cadaveric model, magnetic resonance (MR) imaging techniques with differing contrast and spatial resolution properties in the evaluation of disruption of the lateral ulnar collateral ligament (LUCL) at the elbow. MATERIALS AND METHODS LUCL tears were surgically created in eight of 28 cadaveric elbow specimens. All specimens underwent 1.5-T MR imaging with the following...
متن کاملComparison of Dixon Sequences for Estimation of Percent Breast Fibroglandular Tissue
OBJECTIVES To evaluate sources of error in the Magnetic Resonance Imaging (MRI) measurement of percent fibroglandular tissue (%FGT) using two-point Dixon sequences for fat-water separation. METHODS Ten female volunteers (median age: 31 yrs, range: 23-50 yrs) gave informed consent following Research Ethics Committee approval. Each volunteer was scanned twice following repositioning to enable a...
متن کاملA Nondestructive Method to Distinguish the Internal Constituent Architecture of the Intervertebral Discs Using 9.4 Tesla Magnetic Resonance Imaging
STUDY DESIGN An in vitro study of the intervertebral disc (IVD) structure using 9.4T magnetic resonance imaging (MRI). OBJECTIVE Investigate the potential of ultrahigh-field strength MRI for higher quality 3-dimensional (3D) volumetric MRI datasets of the IVD to better distinguish structural details. SUMMARY OF BACKGROUND DATA MRI has the advantages of being nondestructive and 3D in compari...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Polish journal of veterinary sciences
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2014