Ambulatory impedance cardiography: a feasibility study.

نویسندگان

  • A Sherwood
  • J McFetridge
  • J S Hutcheson
چکیده

A wearable, ambulatory impedance monitor (AIM) has been developed to permit impedance cardiographic measurements while patients and volunteers engage in normal daily activities. The AIM system was developed for use with a new hybrid tetrapolar spot-band electrode configuration and was designed to be comfortable and inconspicuous. The objective of the present study was to provide a preliminary evaluation of AIM comparability with the widely validated Minnesota model 304B impedance cardiograph with standard tetrapolar band electrodes. Orthostatic challenge was used to systematically alter cardiac function in a laboratory setting in 11 healthy men and women. Both while the subjects were sitting and while they were standing, the AIM yielded measures of cardiac function, including heart rate, preejection period, left ventricular ejection time, and stroke volume, that were similar to those acquired by using the reference Minnesota 304B system (all Pearson R correlations > +0.87, all P < 0. 001). Cardiac responses to postural shift, expressed as change measures from sitting to standing, were also comparable for the AIM and Minnesota reference monitoring systems. Potential applications, including the assessment of 24-h hemodynamic profiles, are illustrated and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Quality of Automatic Artifact Identification in Ambulatory Impedance Cardiography Monitoring

In Ambulatory Impedance Cardiography (AICG), a large number of motion artifacts might occur in recordings collected during exercises. The adequate identification of the artifacts is the most important task for automatic analysis of the AICG signals. The aim of this study was to manually assess the efficiency of the classification algorithm described in our earlier papers. We intended to identif...

متن کامل

Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography.

UNLABELLED Recently, devices have become available that allow non-invasive measurement of stroke volume and cardiac output through ambulatory thorax impedance recording. If such recordings have adequate temporal stability, they offer great potential to further our understanding of how repeated or chronic cardiovascular activation in response to naturalistic events may contribute to cardiovascul...

متن کامل

Large-scale ensemble averaging of ambulatory impedance cardiograms.

Impedance cardiography has been used increasingly to measure human physiological responses to emotional and mentally engaging stimuli. The validity of large-scale ensemble averaging of ambulatory impedance cardiograms was evaluated for preejection period (PEP), interbeat interval, and dZ/dt(min) amplitude. We tested whether the average of "classical" 60-sec ensemble averages across periods with...

متن کامل

Hemodynamic profile, compensation deficit, and ambulatory blood pressure.

This study hypothesized that physiologically grounded patterns of hemodynamic profile and compensation deficit would be superior to traditional blood pressure reactivity in the prediction of daily-life blood pressure. Impedance cardiography-derived measures and beat-to-beat blood pressure were monitored continuously in 45 subjects during baseline and four tasks. Ambulatory blood pressure measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 85 6  شماره 

صفحات  -

تاریخ انتشار 1998