Comparison of Two Core Biopsy Techniques Before and After Laparoscopic Cryoablation of Small Renal Cortical Neoplasms

نویسندگان

  • Matthew D. Truesdale
  • Adam C. Mues
  • Samantha Sartori
  • Cristin N. Casazza
  • Gregory W. Hruby
  • Lara R. Harik
  • Kathleen M. O’Toole
  • Ketan K. Badani
  • Alberto Pérez-Lanzac
  • Jaime Landman
چکیده

INTRODUCTION Cryoablation is an acceptable treatment option for small renal cortical neoplasms (RCN). Unlike extirpative interventions, intraoperative needle biopsy is the only pathologic data for ablated tumors. It is imperative that sampled tissue accurately captures pathology. We studied the optimal intraoperative needle core biopsy protocol for small RCN during laparoscopic renal cryoablation (LCA). METHODS Patients with RCN<4cm underwent intraoperative biopsy during LCA. Four biopsy cores were taken per tumor, 2 before and 2 after LCA by using both a standard and modified technique. Standard technique: needle biopsy device was deployed after insertion into the renal tissue at a depth of 5mm. Modified technique: needle biopsy device was deployed 1mm outside of the renal tissue. Biopsies were examined and compared with reference standard pathology. Percentage agreement was calculated across biopsy types (standard vs. modified) and time points (pre- vs. postcryoablation). Logistic regression was used to identify factors impacting biopsy accuracy. RESULTS Thirty patients with 33 RCNs underwent LCA. The mean patient age was 69.1±8.0yrs, and mean tumor size was 2.3±0.7cm. No significant bleeding resulted from biopsies. A definitive diagnosis was made in 31/33 RCNs (94.0%). Ten tumors (30.3%) were benign, 21 (63.7%) were malignant, and 2 (6.0%) were nondiagnostic. Biopsy length was significantly longer using the standard vs. modified technique with mean lengths of 9.3mm vs. 7.0mm, respectively (P=.02). Highest agreement was seen in preablation biopsies (90.3%). A significant association with agreement was seen for younger age (P=.05) and larger tumor size (P=.02). CONCLUSIONS Younger age and larger tumor size were associated with improved accuracy. Preoperative sampling resulted in superior accuracy and the standard technique resulted in significantly longer cores. Use of preablation standard biopsy technique may result in the most accurate pathologic diagnosis for patients undergoing cryoablation for small RCNs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Renal Cryoablation Application in Nephron-sparing Treatment

Purpose: Renal cryoablation is an evolving nephron-sparing treatment alternative for select patients with small renal tumors. Initially described via either an open or percutaneous technique, renal cryoablation has been performed by a laparoscopic approach with promising results. We critically review the cumulative evidence available regarding this technique. Materials and Methods: A review of ...

متن کامل

BioGlue Surgical Adhesive as a Thermal Reflector During Laparoscopic Cryoablation: Effect on Iceball Size and Ablation Zone Diameter

BACKGROUND AND OBJECTIVES Cryoablation represents an alternative for treating small renal cortical neoplasms (RCN). Previously, we demonstrated that applying BioGlue during cryoablation diminished bleeding and incidentally noted that the iceballs seemed larger than those in controls. We examined the effects of BioGlue as a thermal insulator of cryoablated tissue to determine its effect on iceb...

متن کامل

The Role of Pathology in Small Renal Mass Laparoscopic Cryoablation

Objective. We evaluated histological outcome of intraoperative biopsies at laparoscopic renal mass cryoablation (LCA), prevalence of peritumoral fat tissue invasion, and risk of tract seeding. Methods. Patients were biopsied 3-5 times (16-gauge). Histology was analyzed by general pathologists and reviewed. Peritumoral fat was histologically examined. The trocar used for biopsy-guidance was exam...

متن کامل

Comparison of laparoscopic and percutaneous cryoablation of renal tumors: a cost analysis.

Cryoablation of renal masses is an evolving in situ ablative technique for the management of localized renal masses and can be performed in a laparoscopic or percutaneous manner. Its usefulness is increasing and correlates with the increasing frequency of incidentally diagnosed renal lesions. At present, this technique has been applied to patients deemed to be poor surgical candidates for extir...

متن کامل

Cryoablation for Small Renal Masses

Advances in imaging techniques (CT and MRI) and widespread use of imaging especially ultrasound scanning have resulted in a dramatic increase in the detection of small renal masses. While open partial nephrectomy is still the reference standard for the management of these small renal masses, its associated morbidity has encouraged clinicians to exploit the advancements in minimally invasive abl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011