Detection of herpes simplex virus by using A549 cells in centrifugation culture with a rapid membrane enzyme immunoassay.
نویسندگان
چکیده
The RAMP herpes simplex virus (HSV) culture confirmation test was compared with immunofluorescence (IF) staining with a specific HSV monoclonal antibody reagent for the detection of HSV in centrifugation culture. The RAMP test detected 47 of 57 IF-positive specimens (sensitivity, 88.6%) and agreed with 217 of 220 IF-negative specimens (specificity, 98.6%). The RAMP test can be performed in less than 15 min and gives an immediate visual result. However, the sensitivity and the false-positive and false-negative results need further investigation.
منابع مشابه
Effect of dexamethasone on detection of herpes simplex virus in clinical specimens by conventional cell culture and rapid 24-well plate centrifugation.
During a 4-month period, two methods for rapid detection of herpes simplex virus (HSV) were examined: (i) pretreatment of A549 cells with dexamethasone for conventional tissue culture (277 specimens) and (ii) 24-well plate centrifugation using A549 cells with and without dexamethasone pretreatment and staining with serotype-specific monoclonal antibodies (Syva Co., Palo Alto, Calif.) after incu...
متن کاملDevelopment of a Western Blot Assay for Detection of Antibodies against HSV Using Purified HSV Virions Prepared by Sucrose Density Gradient
Objective(s) Herpes simplex viruses (HSVs) have widespread and ubiquitous prevalence in the human population and they have received a great deal of attention due to the range of diseases, they caused as a result of an infection. It seems that the fast and reliable diagnostic methods are needed for detecting the herpes simplex virus type 1 (HSV1) antibodies especially in patients with HSV encep...
متن کاملLoop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملDetection of herpes simplex virus by the Kodak SureCell Herpes Test.
The Kodak SureCell Herpes Test Kit (SC-HSV) was evaluated in a high-risk sexually transmitted disease clinic population. A total of 97 lesion specimens (from 94 patients) were tested for the presence of herpes simplex virus by SC-HSV and by spin-amplified tissue culture confirmed by an enzyme immunoassay. The overall sensitivity of SC-HSV compared with that of spin-amplified tissue culture-enzy...
متن کاملTzanck smears in herpes simplex virus infections
Background: The diagnosis of herpes simplex virus may requirevirological confirmation. Tzanck smear is an old, rapid, costeffective but nonspecific method that has been recently re-evaluatedas a method for the diagnosis of herpes virus infection. This studywas conducted to compare Tzanck smear and viral culture in thediagnosis of herpes simplex virus infection in patients clinicallysuspected to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 27 7 شماره
صفحات -
تاریخ انتشار 1989