2010: IgG biofilm adsorption is influenced by Cobalt wear debris size and can increase IL-1beta production in macrophages
ثبت نشده
چکیده
INTRODUCTION: Metallic implant debris may exist in vivo as particles (micrometers to nanometers in size), or colloidal and ionic forms of metal (specifically or nonspecifically bound by protein). The biocompatibility of metallic implant surfaces is governed in large part by the interfacial kinetics associated with protein binding. (1) Immediately upon implantation, biomaterial surfaces complex with proteins forming a protein biofilm. The composition of adsorbed proteins and subsequent cell-material interactions are determined by the physiochemical properties of the biomaterial. (1) Because the biofilm is an intermediary between biomaterial surfaces and host tissue, it is necessary to characterize the interface in terms of the adsorbed biofilm. Previous studies showed differences in protein binding based on differences in the type of material (metal vs polymer and Ti-alloy vs Co-alloy) (1). Can these differences in protein binding exist in a specific metal of different size particles? Previous studies implicated interactions between IgG proteins and alloy surfaces as an inducer of bioreactivity. We hypothesized that a given implant alloy will show differences in protein biofilm based on particle size alone (when analyzed on an equal surface area basis) and that these biofilm difference will impact bioreactivity in vitro, where IgG biofilms will induce greater bioreactivity than other common serum proteins (Albumin). We tested this hypothesis by analyzing the biofilm of 2 sizes of Co-alloy particles in human serum and by altering the biofilm of a single size of Co-alloy particles and measuring the consequent bioreactivity. MATERIALS AND METHODS: N=6 subjects were consented and used to obtain human serum for biofilm and bioreactivity testing. To assess biofilm differences two sizes of CoCrMo implant alloy (ASTM F75) spherical particles were used: diameters of (1-5um) ≈4.7um and ≈70um (volume basis, mv) (Bioengineering Solutions Inc.). Equal surface areas were used to assess biofilm adsorption with each size type: 100 cm. Particles were incubated for 4 days in serum provided by 6 subjects. Beads were gently washed with PBS 2x, to remove nonadherent proteins then biofilm proteins were eluted with 2% SDS solution for 24 hours. Samples were then separated and analyzed by 1-d SDS gel 10-20% (Bio-Rad). Coomassie blue stained gels were analyzed using NIH scion image to determine protein amounts compared to known standards (Bio-Rad). To determine the bioreactivity of biofilm differences found in the first part of this study, a comparative study examined the effects of fibronectin, serum, albumin, IgG and LPS biofilms incubated with 1 micron-sized particles dosed at 5 particles/cell on early cytokine TNF-alpha and 24-hour IL-1beta cytokine release in autologous primary human monocytes/macrophages (n=5). RESULTS: The eluted biofilm gels of 3 subjects are shown in Fig 1. Data analsysis of the 140kD band is shown in Fig. 2. Biofilms of the specimens from all 6 subjects demonstrated compositional and total differences in amount of serum proteins adsorbed onto Co-based alloy beads. Densitometric analysis of the biofilm protein bands revealed that the only statistically significant difference in the intensity of protein(s) binding between the metals was in 140 kDa molecular weight (rectangular box present in Fig 1) (p < 0.05) (when represented as a percentage of total serum protein adsorbed). Normalization was used to account for introduced and inherent variability in total protein between subjects. There was subject-dependent variation in the total protein adsorbed onto the metal surfaces, despite identical processing of all samples possibly related to endogenous constitutive protein differences. Thus there were no significant size-dependent differences in total amounts of bound proteins, but more samples are necessary to corroborate this phenomenon. Bioreactivity of albumin and IgG biofilm differences using 1um sized Co-alloy particles were assessed using primary monocytes/macrophages and the results of TNF-α and IL-1β are shown in Figs. 3 and 4. Biofilm differences induced statistically significant differences in IL-1β secretion and increased significant differences in the albumin secretion of TNF-α over that of IgG (results for one of 5 individuals shown, Fig 4). DISCUSSION: The results of this investigation only partially supported our original hypothesis. We did identify particle-size based dependence of serum bioflims. However when these biofilm differences were imposed on particles of the same size (1um), they did not induce bioreactivity differences. Smaller sized particles (5um) preferentially bound large range proteins especially in ≈140kD range as did larger particles (70um). Since this characteristic was consistent with all subjects it seems that other surface characteristics (e.g. surface charge density, microstuctural variation, etc.) rather than alloy composition (i.e.Co-alloy) play a role in differential binding. The lack of influence of biofilm composition on cytokine production was unexpected. In all subjects IgG biofilms did not play as significant a role in TNF-alpha production as did albumin. A mix of serum proteins which includes IgG were shown to play a more important role in eliciting an inflammatory response (inflammasome induced IL-1β, Fig 4). Further testing using Western blot, 2D-PAGE, and Mass Spec analyses are the focus of current efforts to more fully identify and investigate biofilm proteins on implant debris and their associated biologic effects. ACKNOWLEDGEMENTS: NIAMS/NIH, Crown Family Chair of Orthopedics REFERENCES: 1. Hallab NJ et al. Systemic metal-protein binding associated with total joint replacement arthroplasty. J Biomed Mater Res 2000;49:353–361.
منابع مشابه
The Effect of MS14 on Production of Pro-inflammatory Cytokines by Macrophages
Objective(s) Using herbal medicines as a complementary treatment method is increasing in wide variety of diseases. MS14-an herbal-marine preparation-is reported to have anti-inflammatory and immunomodulatory activities; however, the mechanism underlying its therapeutic effect is not known. Macrophages play an important role in host defense mechanisms and carry out their role by producing vario...
متن کاملAcute inflammatory response to cobalt chromium orthopaedic wear debris in a rodent air-pouch model.
This study used a rodent air-pouch model to assess the acute inflammatory response to cobalt-chromium (CoCr) alloy wear debris from a metal-on-metal hip resurfacing implant that may contribute to joint failure. Air-pouches were injected with either sterile phosphate-buffered saline, 1 μg lipopolysaccharide (LPS) or 2.5 mg CoCr wear debris. The in situ inflammatory response was monitored 4, 24, ...
متن کاملRegulatory effects of endogenous interleukin-1 receptor antagonist protein in immunoglobulin G immune complex-induced lung injury.
IL-1 receptor antagonist (IL-1Ra) has regulatory effects on IL-1 activity both in vitro and in vivo. In the IgG immune complex model of lung injury in rats, exogenously administered human IL-1Ra suppressed neutrophil recruitment and ensuing lung injury. In this study, we sought to determine if endogenous rat IL-1Ra might regulate this lung-inflammatory response. By Northern blot analysis of lun...
متن کاملToxicity of cobalt-chromium nanoparticles released from a resurfacing hip implant and cobalt ions on primary human lymphocytes in vitro.
Adverse tissue responses to prostheses wear particles and released ions are important contributors to hip implant failure. In implant-related adverse reactions T-lymphocytes play a prominent role in sustaining the chronic inflammatory response. To further understand the involvement of lymphocytes in metal-on-metal (MoM) implant failure, primary human lymphocytes were isolated and treated with c...
متن کاملBiologic effects of implant debris.
Biologic response to orthopedic implants debris is central to clinical performance. Eventual implant loosening due to aseptic osteolysis has been attributed to local inflammatory responses to wear and corrosion products that are produced by articulating implant interfaces. The response to implant debris is dominated by local immune activation, e.g. macrophages. Immune reactivity has been shown ...
متن کامل