A novel USP apparatus 4 based release testing method for dispersed systems.

نویسندگان

  • Upkar Bhardwaj
  • Diane J Burgess
چکیده

A novel dialysis adapter has been developed for USP apparatus 4 for in vitro release testing of dispersed system dosage forms. This USP apparatus 4 method was optimized and compared with currently used dialysis and reverse dialysis sac methods. Optimization studies for the USP apparatus 4 method showed that release from solution, suspension and liposome formulations was not flow rate limited and was not affected by change in the dialysis adapter sample volume from 250microl to 500microl. The USP apparatus 4 method could discriminate between solution, suspension and liposome formulations of dexamethasone. On comparing the different methods, only the USP apparatus 4 method provided discrimination between dexamethasone release from extruded and non-extruded liposomes, as well as among non-extruded DMPC, DPPC and DSPC liposomes. The dialysis sac method could not discriminate between the release profiles of non-extruded DMPC and DPPC liposomes. The reverse dialysis sac could not discriminate between the release profiles of extruded and non-extruded DMPC liposomes. In addition, the USP apparatus 4 method provided the highest release and the smallest variation in the data. This novel adapter might address the problem of the lack of a compendial apparatus for in vitro release testing of dispersed system dosage forms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Optimization of Novel Sugar Alcohol Based Extended Release Tablets Prepared by Melt Dispersion Technique

     The aim of this study is to prepare novel sorbitol based extended release tablets by melt dispersion method using carbamazepine as a model drug. Carbamazepine was melted along with sugar alcohol to get melt dispersion granules (MGDs) and was characterized by differential scanning calorimetry (DSC), powder X-ray diffractometry (XRD) and solubility study. The physical and chemical parameters...

متن کامل

Application of a novel symmetrical shape factor to gastroretentive matrices as a measure of swelling synchronization and its impact on drug release kinetics under standard and modified dissolution conditions.

OBJECTIVES We have assessed the kinetics of drug release in relation to the full or partial hydration and swelling of matrices under standard and modified United States Pharmacopeia (USP) apparatus II using a novel index, defined as the symmetrical shape factor. The symmetrical shape factor describes the regularity of the hydration rate of the matrix perimeter relative to its central regions. ...

متن کامل

The Comparison of In Vitro Release Methods for the Evaluation of Oxytocin Release from Pluronic® F127 Parenteral Formulations

The objective of these studies was to develop a discriminatory in vitro release test for assessing formulation factors that may affect oxytocin (OT) release during formulation development studies of a Pluronic® F127 OT in situ gel-forming parenteral dosage form. An appropriate release assessment method should be able to discriminate between the performance of different formulation compositions ...

متن کامل

Experimental and Computational Study on Hydrodynamic of a Downscaled Mini Vessel USP Dissolution Test Apparatus II

Although not listed on the United States Pharmacopeia (USP), like standard USP 2, small volume USP 2 dissolution apparatus has gained a great deal of attention, especially for cases where small amount of drug product is available for testing in research and design step or evaluations are to be made on a tablet containing trace amounts of the active pharmaceutical ingredient. In this work, first...

متن کامل

Development and Validation of a Discriminating Dissolution Method for Atorvastatin Delayed-Release Nanoparticles Using a Flow-Through Cell: A Comparative Study Using USP Apparatus 4 and 1

Atorvastatin, an HMG CoA reductase inhibitor, is widely used for the treatment of dyslipidemia and prevention of cardiovascular disease. It belongs to Class 2 of the Biopharmaceutics Classification System owing to its low solubility and high permeability. In vitro dissolution testing is an essential tool for the design of a dosage form. Appropriate selection of dissolution test conditions is es...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of pharmaceutics

دوره 388 1-2  شماره 

صفحات  -

تاریخ انتشار 2010