The biomechanics of trans-femoral amputation.
نویسندگان
چکیده
The biomechanics of trans-femoral amputations has not been previously described. Little attention has been paid to the importance of adductor magnus in holding the femur in its normal anatomical axis. Loss of function of adductor magnus leads to abduction of the residual femur, in a trans-femoral amputation. A cadaver study of the adductor group of thigh muscles has been done and the biomechanical importance of these muscles is documented. The moment arms of the three adductor muscles have been determined, based on muscle attachments and muscle size, relative to each other. Adductor magnus has a major mechanical advantage in holding the thigh in its normal anatomical position. Loss of the distal third of its attachment results in a 70% loss of the effective moment arm of the muscle, which contributes to the abducted femur in standard trans-femoral amputations. A muscle preserving trans-femoral amputation, which keeps adductor magnus intact, prevents abduction of the residual femur and may allow for easier walking with a prosthesis. The conflicting reports about adductor magnus activity during the gait cycle can be explained by this muscle's dual innervation by the sciatic and obturator nerves and its dual function as a hip adductor and extensor.
منابع مشابه
Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait.
The biomechanical interaction between the leg stump and the prosthetic socket is critical in achieving close-to-normal ambulation. Although many investigations have been performed to understand the biomechanics of trans-tibial sockets, few studies have measured the socket interface pressure for transfemoral amputees. Furthermore, no report has examined how the residual muscle activities in the ...
متن کاملJoint loading and bone mineral density in persons with unilateral, trans-tibial amputation.
BACKGROUND Persons with unilateral, lower-extremity amputation sometimes develop osteoarthritis in the intact limb. The purpose of this study was to investigate gait mechanics and bone mineral density in unilateral, trans-tibial amputees to test the hypotheses that the intact limb knee and hip will have larger frontal plane net joint moments and bone mineral density than the prosthetic side and...
متن کاملNumerical evaluation of bone remodelling associated with trans-femoral osseointegration implant--A 68 month follow-up study.
Osseointegrated trans-femoral implant is a relatively new orthopaedic anchoring method for connecting a stump with a prosthesis. Through a follow-up study of a patient over six years, significant bone remodelling has been observed. Finite element (FE) simulations were carried out to investigate the relationship between the bone remodelling and the strain re-distribution around the trans-femoral...
متن کاملStump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
A system for measuring the stump-socket interface pressure was designed and built using a strain gauged type load cell. The system was utilized to study the pressure distribution in the quadrilateral and ischial containment type sockets. Two volunteer trans-femoral amputees fitted with both types of socket participated in the experiments. Pressures were measured while the subjects were standing...
متن کاملThe impact of gender, level of amputation and diabetes on prosthetic fit rates following major lower extremity amputation
BACKGROUND Diabetes mellitus is a leading cause of major lower extremity amputation. OBJECTIVE To examine the influence of gender, level of amputation and diabetes mellitus status on being fit with a prosthetic limb following lower extremity amputation for peripheral arterial disease. STUDY DESIGN Retrospective analysis of the Scottish Physiotherapy Amputee Research Group dataset. RESULTS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Prosthetics and orthotics international
دوره 18 1 شماره
صفحات -
تاریخ انتشار 1994