Quantifying the geometry correction factor and effectiveness parameter for Bonner sphere spectrometer with He counter
نویسندگان
چکیده
This paper presents the evaluation of the geometry correction factor for calibration of Bonner sphere spectrometer (BSS) equipped with the He counter (typical SP9), based on Monte Carlo simulation. Using the MCNP4C code, geometry factors and effectiveness parameters (d) of a 800 polyethylene sphere (r = 10.16 cm) were calculated for 10 different energies and 3 various distances between the source and center of the sphere. The obtained results showed that the geometry factor increases with the distance, and the effectiveness parameter is independent of distance. Finally, for 200, 300, 500, 800 and 1200 spheres exposed to four different radio-isotopic neutron sources with various energy spectrums, the effectiveness parameters were determined, which it is worthy to consider d : d(r, E).
منابع مشابه
Features of the AmBe-based UPM neutron facility
A new automated bench for irradiation, using a AmBe neutron source, has been installed in the neutronics hall at the Universidad Politécnica de Madrid (UPM). In order to determine the neutron field features on the bench a neutron spectrometry, using the Bonner sphere spectrometer, campaign was carried out with the participation of four research teams. Each team used their own spectrometer with ...
متن کاملSequential monitoring of cosmic-ray neutrons and ionizing components in Japan
A fixed-point measurement of cosmic-ray intensity has being continued at Chiba, near Tokyo in Japan to obtain the time-sequential data. High efficiency neutron rem counter and Multi-sphere neutron Spectrometer (Bonner Sphere: BS) were used for the measurement of cosmic-ray neutron components and for the evaluation of the cosmic-ray ionizing components, NaI(Tl) scintillation spectrometer was emp...
متن کاملAltitude Variation of cosmic-ray neutron energy spectrum and ambient dose equivalent at Mt
The experimental studies on the cosmic-ray neutron energy spectrum and the neutron dose rate were performed in the Mt.Fuji area (altitude: 40m – 2400m) by using a Multi-sphere neutron Spectrometer (Bonner Sphere: BS) with the 5.07-cm diam. spherical He-3 proportional counter to assess the natural background neutron dose rate in Japan with good accuracy. The spectra measured at each altitude wer...
متن کاملComparison of unfolding codes for neutron spectrometry with Bonner spheres.
This work compares the results of four different unfolding codes, MSANDB, MAXED, FRUIT and BONMA, which are based on different unfolding techniques. Additionally, Bayesian parameter estimation is also considered. All unfolding codes were supplied with the same set of input data acquired at the Environmental Research Station 'Schneefernerhaus' on the Zugspitze mountain, corresponding to continuo...
متن کاملResponse matrix evaluations of a passive Bonner sphere system used for neutron spectrometry at pulsed, intense and complex mixed fields
In the present work, the general purpose radiation transport MCNPX code (version 2.5.0) was used to evaluate the neutron fluence response matrix of the passive Bonner sphere spectrometer recently developed in our laboratory. The calculations were performed for an extended neutron incidence energy range (from 10−9 MeV to 1 GeV). Afterward, a sensitivity analysis of the main parameters affecting ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -