Diagnostic accuracy and reproducibility of pleural and lung ultrasound in discriminating cardiogenic causes of acute dyspnea in the emergency department.
نویسندگان
چکیده
Dyspnea is a common symptom in patients admitted to the Emergency Department (ED), and discriminating between cardiogenic and non-cardiogenic dyspnea is often a clinical dilemma. The initial diagnostic work-up may be inaccurate in defining the etiology and the underlying pathophysiology. The aim of this study was to evaluate the diagnostic accuracy and reproducibility of pleural and lung ultrasound (PLUS), performed by emergency physicians at the time of a patient's initial evaluation in the ED, in identifying cardiac causes of acute dyspnea. Between February and July 2007, 56 patients presenting to the ED with acute dyspnea were prospectively enrolled in this study. In all patients, PLUS was performed by emergency physicians with the purpose of identifying the presence of diffuse alveolar-interstitial syndrome (AIS) or pleural effusion. All scans were later reviewed by two other emergency physicians, expert in PLUS and blinded to clinical parameters, who were the ultimate judges of positivity for diffuse AIS and pleural effusion. A random set of 80 recorded scannings were also reviewed by two inexperienced observers to assess inter-observer variability. The entire medical record was independently reviewed by two expert physicians (an emergency medicine physician and a cardiologist) blinded to the ultrasound (US) results, in order to determine whether, for each patient, dyspnea was due to heart failure, or not. Sensitivity, specificity, and positive/negative predictive values were obtained; likelihood ratio (LR) test was used. Cohen's kappa was used to assess inter-observer agreement. The presence of diffuse AIS was highly predictive for cardiogenic dyspnea (sensitivity 93.6%, specificity 84%, positive predictive value 87.9%, negative predictive value 91.3%). On the contrary, US detection of pleural effusion was not helpful in the differential diagnosis (sensitivity 83.9%, specificity 52%, positive predictive value 68.4%, negative predictive value 72.2%). Finally, the coexistence of diffuse AIS and pleural effusion is less accurate than diffuse AIS alone for cardiogenic dyspnea (sensitivity 81.5%, specificity 82.8%, positive predictive value 81.5%, negative predictive value 82.8%). The positive LR was 5.8 for AIS [95% confidence interval (CI) 4.8-7.1] and 1.7 (95% CI 1.2-2.6) for pleural effusion, negative LR resulted 0.1 (95% CI 0.0-0.4) for AIS and 0.3 (95% CI 0.1-0.8) for pleural effusion. Agreement between experienced and inexperienced operators was 92.2% (p < 0.01) and 95% (p < 0.01) for diagnosis of AIS and pleural effusion, respectively. In early evaluation of patients presenting to the ED with dyspnea, PLUS, performed with the purpose of identifying diffuse AIS, may represent an accurate and reproducible bedside tool in discriminating between cardiogenic and non-cardiogenic dyspnea. On the contrary, US detection of pleural effusions does not allow reliable discrimination between different causes of acute dyspnea in unselected ED patients.
منابع مشابه
Lung Ultrasound for diagnosis of acute cardiogenic dyspnea in the Emergency Department – a simeu multicenter study
Introduction Acute dyspnea is among the most common presentations to the Emergency Department (ED). Discriminating between cardiac and non-cardiac causes of dyspnea can sometimes be challenging. Lung Ultrasound (LUS), integrated with standard clinical evaluation (i.e. history, physical examination, EKG and arterial blood gas iLUS) has emerged as a non-invasive bedside valuable technique for dia...
متن کاملThree-view bedside ultrasound for the differentiation of acute respiratory distress syndrome from cardiogenic pulmonary edema.
Bedside ultrasound is being increasingly used by emergency physicians (EPs) for the differentiation of acute dyspnea in critically ill patients. Lung ultrasound is emerging as a highly sensitive tool in diagnosing alveolar interstitial edema with the presence of diffuse “B-lines” arising from the pleural line. However, when used independently, lung ultrasound is unable to differentiate between ...
متن کاملDiagnostic Accuracy of Acute Appendicitis by Ultrasound in Hospital Emergency
Background Acute appendicitis is the most common medical condition requiring immediate abdominal surgery.Medical ultrasound is a non-intrusive, non-expensive and available diagnostic method. In this study, the accuracy of ultrasound in diagnosis of acute appendicitis in hospital emergency was evaluated. Materials and Methods This retrospective cohort study was performed at Ahvaz Imam Khomeini h...
متن کاملAcute cardiogenic dyspnea in the emergency department: accuracy of lung ultrasound
Patients and methods 70 patients presenting with acute dyspnea have been enrolled. On admission every patient underwent to LUS and chest X-ray (CXR). Ultrasound findings of Interstitial Alveolar Syndrome (IAS), which correlate with an increase in interstitial lung water, were reported. On the results of LUS, the patients were attributed to 2 different diagnostic groups: Group 1: patients with c...
متن کاملDyspnea in Patient with Arteria Lusoria: A Case Report
Introduction: Arteria lusoria is an aberrant right subclavian artery. In symptomatic cases, patients report dysphagia and only in few cases dyspnea, due to external compression of the trachea and esophagus. Symptoms occur in advanced age and diagnosis is made with chest HRCT, when other causes of dysphagia have been excluded. Case Report: An 83-year-old woman presented with dyspnea and m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Internal and emergency medicine
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2012