A Conversion Formula for Comparing Pulse Oximeter Desaturation Rates Obtained with Different Averaging Times

نویسندگان

  • Jan Vagedes
  • Anja Bialkowski
  • Cornelia Wiechers
  • Christian F. Poets
  • Klaus Dietz
چکیده

OBJECTIVE The number of desaturations determined in recordings of pulse oximeter saturation (SpO2) primarily depends on the time over which values are averaged. As the averaging time in pulse oximeters is not standardized, it varies considerably between centers. To make SpO2 data comparable, it is thus desirable to have a formula that allows conversion between desaturation rates obtained using different averaging times for various desaturation levels and minimal durations. METHODS Oxygen saturation was measured for 170 hours in 12 preterm infants with a mean number of 65 desaturations <90% per hour of arbitrary duration by using a pulse oximeter in a 2-4 s averaging mode. Using 7 different averaging times between 3 and 16 seconds, the raw red-to-infrared data were reprocessed to determine the number of desaturations (D). The whole procedure was carried out for 7 different minimal desaturation durations (≥ 1, ≥ 5, ≥ 10, ≥ 15, ≥ 20, ≥ 25, ≥ 30 s) below SpO2 threshold values of 80%, 85% or 90% to finally reach a conversion formula. The formula was validated by splitting the infants into two groups of six children each and using one group each as a training set and the other one as a test set. RESULTS Based on the linear relationship found between the logarithm of the desaturation rate and the logarithm of the averaging time, the conversion formula is: D2 = D1 (T2/T1)(c), where D2 is the desaturation rate for the desired averaging time T2, and D1 is the desaturation rate for the original averaging time T1, with the exponent c depending on the desaturation threshold and the minimal desaturation duration. The median error when applying this formula was 2.6%. CONCLUSION This formula enables the conversion of desaturation rates between different averaging times for various desaturation thresholds and minimal desaturation durations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sleep desaturation: comparison of two oximeters.

Oxygen saturation is measured by pulse oximetry during sleep studies. Body movements and peripheral vasoconstriction related to respiratory events may interfere with measurements by conventional oximeters. Our objective was to compare the detection rate of sleep desaturations by two oximeters, one of which used new motion-resistant technology. We studied 34 children (median age, 13 years; range...

متن کامل

Choice of oximeter affects apnea-hypopnea index.

STUDY OBJECTIVES Current Medicare guidelines include an apnea-hypopnea index (AHI) > or = 15 events per hour, in which all hypopneas must be associated with 4% desaturation, to qualify for reimbursement for therapy with continuous positive airway pressure (CPAP). The present data demonstrate the effect of pulse oximeter differences on AHI. DESIGN Prospective study, blinded analysis. SETTING...

متن کامل

Arterial oxygen desaturation after induction of anesthesia.

To the Editor:—Naguib et al. have presented a clinically relevant study of arterial saturation values after preoxygenation and different doses of suxamethonium, and discuss their results using the extensive reports relevant to this topic. Unfortunately, they perhaps did not search the published work back to times before the pulse oximeter was introduced. Before the pulse oximeter, the Hewlett P...

متن کامل

Continuous auditory monitoring--how much information do we register?

We have studied response times of 30 anaesthetists to a standardized episode of arterial oxygen desaturation in a simulated patient, randomized to the use of either a fixed or variable pitch pulse oximeter. We wished to determine if a variable auditory signal was important in detecting adverse events. A variable pitch pulse signal had a shorter time to recognition of desaturation (P < 0.0001), ...

متن کامل

Performance of three new-generation pulse oximeters during motion and low perfusion in volunteers.

STUDY OBJECTIVE To evaluate pulse oximeter performance during motion and induced low perfusion in volunteers. DESIGN Prospective volunteer study. SETTING Direct Observation unit. SUBJECTS 10 healthy adult volunteers. INTERVENTIONS Ten volunteers were monitored with three different pulse oximeters while they underwent desaturation to about 75% oxygen saturation (SpO(2)) and performed mac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014