The effects of hemolysis on plasma prothrombin time and activated partial thromboplastin time tests using photo-optical method

نویسندگان

  • Yetti Hernaningsih
  • Jeine Stela Akualing
چکیده

Hemolysis is the most common reason why coagulation test samples are rejected. However, the effects of hemolysis on plasma prothrombin time (PPT) and activated partial thromboplastin time (APTT) are rarely investigated and the results are controversial. This research aims to analyze the effects of hemolysis on PPT and APPT using the photo-optical method.Nonhemolyzed citrate blood samples (n = 30) with normal PPT and APTT underwent 2-step mechanical lysis and then hemoglobin level measurement was carried out at each step. The first lysis was mild to moderate resulting in a hemoglobin level of <0.8 g/dL. These samples were labeled as group 1. The second step showed more severe lysis, which resulted in a plasma hemoglobin level of ≥0.8 g/dL. These samples were labeled as group 2. Analysis was carried out on the PPT and APTT differences between the 2 groups and baseline, as well as between group 1 and group 2 using repeated-measures analysis of variance (ANOVA). The effects of hemolysis were analyzed using linear regression. Receiver operating characteristic (ROC) curve analysis was performed to determine the cut-off value in PPT and APTT.Significantly shorter APTT was measured for group 1 than baseline, (P = .000), group 2 than baseline (P = .000), and group 2 than group 1 (P = .003). With regard to PPT results, those for group 1 were significant shorter than baseline (P = .002), while those for group 2 were significantly longer than group 1 (P = .000). In the correlation assay, the level of hemolysis revealed a mildly significant correlation to APTT (R = 0.245; P = .02). Cut-off value for PPT was 1.55 g/dL (100% sensitivity and 87.9% specificity), while the value for APTT was 0.95 g/dL (75% sensitivity and 62.5% specificity).Not all hemolyzed samples should be rejected for PPT and APTT tests using photo-optical methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی خون سازگاری سطح اپی تلیال پرده آمنیون در مقایسه با رگ صناعی (پلی تترافلورواتیلن)

Background and purpose: Amniotic membrane (AM) is a proper candidate for vascular tissue engineering. The aim of this study was to evaluate the hemocompatibility of the epithelial surface of the AM. Materials and methods: In this study, we assessed the effects of the epithelial surface of the AM on blood coagulation system by measuring activated partial thromboplastin time (aPTT), prothromb...

متن کامل

Evaluation of Antiphospholipid Antibodies and Activated Partial Thromboplastin Time in Women with Adverse Outcome of Pregnancy

Adverse outcome of pregnancy is a potentially dangerous complication of conception and affects 15-20% of pregnancies. According to recent studies increased level of blood antiphospholipids antibodies, if accompanied by predisposing factors, can be an adverse event in human pregnancy. The aim of the present study was to compare the maternal serum levels of anticardiolipin and antiphosphatidyl se...

متن کامل

Microcantilever Based Loc System for Coagulation Measurements

In this paper, a microcantilever-based system enabling multiple coagulation tests on the same disposable cartridge is demonstrated. The system consists of independent cartridge and reader unit. The actuation of the nickel cantilevers is conducted remotely with an external electro-coil and remote optical read-out is utilized for sensing. Both Prothrombin Time (PT) and activated Partial Thrombopl...

متن کامل

Effect of Fondaparinux on Coagulation Assays

● Context.—Fondaparinux, a factor Xa inhibitor, is approved for thromboprophylaxis after orthopedic surgery and for treatment of venous thromboembolism. It may also be efficacious, safe, and cost-effective for other patients; thus, more widespread use of fondaparinux is likely. The effect of fondaparinux on coagulation testing needs to be thoroughly examined. Objective.—To report the effects of...

متن کامل

The effect of specimen hemolysis on coagulation test results.

Hemolyzed specimens are rejected for coagulation testing based on concerns of artifactual interference. Prothrombin time (PT), activated partial thromboplastin time (aPTT), and selected factor assay test results for consecutive pairs of hemolyzed and subsequently recollected (mean, 72 minutes later) nonhemolyzed patient specimens were compared. Specimens from healthy human subjects were subject...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017