BACKGROUND The Bonfils intubation fibrescope is a promising alternative device for securing the airway. We examined the success rate of intubation and the ease of use in standardized simulated difficult airway scenarios by physicians. We compared the Bonfils to a classical laryngoscope with Macintosh blade. METHODS 30 physicians untrained in the use of rigid fibrescopes but experienced in airway management performed endotracheal intubation in an airway manikin (SimMan, Laerdal, Kent, UK) with three different airway conditions. We evaluated the success rate using the Bonfils (Karl Storz, Tuttlingen, Germany) or the Macintosh laryngoscope, the time needed for securing the airway, and subjective rating of both techniques. RESULTS In normal airway all intubations were successful using laryngoscope (100%) vs. 82% using the Bonfils (p < 0.05). In the scenario "tongue oedema" success rate using the Macintosh laryngoscope was 67% and 83% using the Bonfils. In the scenario "decreased cervical range of motion with jaw trismus", success rate using the Macintosh laryngoscope was 84% vs. 76%. In difficult airway scenarios time until airway was secured did not differ between the two devices. Use of Bonfils was rated "easier" in both difficult airway scenarios. CONCLUSION The Bonfils can be successfully used by physicians unfamiliar with this technique in an airway manikin. The airway could be secured with at least the same success rate as using a Macintosh laryngoscope in difficult airway scenarios. Use of the Bonfils did not delay intubation in the presence of a difficult airway. These results indicate that intensive special training is advised to use the Bonfils effectively in airway management.
منابع مشابه
Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway.
BACKGROUND The Bonfils intubation fibrescope (BIF), a rigid, straight and reusable fibreoptic device, is being used increasingly to facilitate endotracheal intubation after direct laryngoscopy has failed. We tested the hypothesis that, with the BIF compared to direct laryngoscopy, the rate of failed endotracheal intubation could be reduced in patients with a difficult airway, simulated by means...
متن کاملComparison of the Airtraq to the Bonfils Fibroscope for Endotracheal Intubation in a Simulated Difficult Airway
Background: Difficult intubation, represent a challenge to anesthetist especially that many cases are encountered after induction of anesthesia. The Airtraq and the Bonfils fibroscopes are new devices designed to facilitate intubation under normal and difficult circumstances. In the present study, the efficacy and the intubation success rate of the Airtraq to the Bonfils fiberscope were evaluat...
متن کاملComparison of the performance of four laryngoscopes in a high-fidelity simulator using normal and difficult airway.
BACKGROUND Novel laryngoscopes may demonstrate advantages over the traditional Macintosh laryngoscope for difficult airways. Our study compared Glidescope laryngoscope, Bonfils fibrescope, and CTrach intubating laryngeal mask airway with the Macintosh laryngoscope in a simulated normal and difficult airway, considering the additional effect of previous intubation experience. METHODS Twenty-tw...
متن کاملImproving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
BACKGROUND The Bonfils intubating fiberscope has a limited upward tip angle of 40 degrees and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The Center for Advanced Technology and Telemedicine ...
متن کاملNasotracheal intubation: look before you leap.
Nasotracheal intubation is frequently used for airway management during maxillofacial surgery. Complications such as haemorrhage occur more frequently with this route of intubation than with the orotracheal route. This case report describes a male patient aged 51 yr who developed severe epistaxis after the tube had passed the nares. As an additional complication laryngoscopy and endotracheal in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
دوره 17 شماره
صفحات -
تاریخ انتشار 2009