Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development
نویسندگان
چکیده
Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical application of an anatomically pre-contoured plate for the treatment of distal fibular fractures based on the anatomical database.48 Caucasian and Asian bone models (left and right) from the database were used for the preliminary optimization process and validation of the fibula plate. The implant was constructed to fit bilaterally in a lateral position of the fibula. Then a biomechanical comparison of the designed implant to the current gold standard in the treatment of distal fibular fractures (locking 1/3 tubular plate) was conducted. Finally, a clinical surveillance study to evaluate the grade of implant fit achieved was performed. The results showed that with a virtual anatomic database it was possible to design a fibula plate with an optimized fit for a large proportion of the population. Biomechanical testing showed the novel fibula plate to be superior to 1/3 tubular plates in 4-point bending tests. The clinical application showed a very high degree of primary implant fit. Only in a small minority of cases further intra-operative implant bending was necessary. Therefore, the goal to develop an implant for the treatment of distal fibular fractures based on the evidence of a large anatomical database could be attained. Biomechanical testing showed good results regarding the stability and the clinical application confirmed the high grade of anatomical fit.
منابع مشابه
Biomechanical Benefits of the VariAx Distal Lateral Fibula Plate
Distal fibula fractures are the most common injury of weight bearing bones. Several studies have shown the benefit of locking plates especially in osteoporotic bone. The aim of this biomechanical study was to test the anatomically shaped VariAx Distal Lateral Fibula Plate in comparison to a commonly used 1/3 Tubular Plate. The implants were assembled to bone surrogates simulating a comminuted f...
متن کاملGravity Reduction View: A Radiographic Technique for the Evaluation and Management of Weber B Fibula Fractures
Background: While various radiographic parameters and application of manual/gravity stress have been proposed to elucidate instability for Weber B fibula fractures, the prognostic capability of these modalities remains unclear. Determination of anatomic positioning of the mortise is paramount. We propose a novel view, the Gravity Reduction View (GRV), which helps elucidate non-anatomic position...
متن کاملRadiological and Histological Assessment of the Ossification Centers of Hind Limb after Hatching in Pigeon
Objective- The aim of this study was to determine the age of physical maturity and evaluation of radiology and histology of hind limb ossification centers in pigeon. Design- Fundamental study. Animals- 14 pigeons. Procedures- These pigeons were cultivated in identical and standard conditions and radiological and histological tests performed every 7 days to 91 days. Resu...
متن کاملOutcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملBiomechanical comparison of 4 different lateral plate constructs for distal fibula fractures.
BACKGROUND Displaced lateral malleolar fractures are often treated with reduction and surgical stabilization. However, there has not been a comprehensive laboratory comparison to determine the most appropriate device for treating these patients. This study subjected a range of contemporary lateral fibular plates to a series of mechanical tests designed to reveal performance differences. METHO...
متن کامل