How does magnification affect image quality and patient dose in digital subtraction angiography?

نویسندگان

  • Nikolaos A Gkanatsios
  • Walter Huda
  • Keith R Peters
چکیده

Digital subtraction angiography (DSA) images were obtained of a phantom containing 1 mm diameter vessels. The iodine concentrations ranged from 5 to 50 mg/cc, which permitted the determination of the detection threshold concentration of iodine. The source to image receptor distance was 105 cm, and image magnification was varied between 1.15 and 2.0. One experiment was performed at an input exposure of 1 μGy per frame, and a second experiment was performed at 4 μGy per frame. Surface (skin) doses were measured using an ionization chamber, and the corresponding values of energy imparted were determined from the exposure area product. Increasing the radiation exposure by a factor of four reduced the threshold iodine concentration by ~30%. The average detection threshold iodine concentration for a magnification of 1.15 was 13.6 mg/cc. Detection performance improved linearly with magnification, with an average value of 7.4 mg/cc at a magnification of 2.0. Values of energy imparted were essentially independent of image magnification, whereas surface doses increased by a factor of four when image magnification was increased from 1.15 to 2.0. Magnification offers improved imaging performance at no additional patient risk provided that surface doses do not exceed the dose threshold for deterministic effects such as skin burns and epilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Dose Reduction without Compromise to Image Quality by Alterations of Filtration and Focal Spot Size in Cerebral Angiography

OBJECTIVE Different angiographic protocols may influence the radiation dose and image quality. In this study, we aimed to investigate the effects of filtration and focal spot size on radiation dose and image quality for diagnostic cerebral angiography using an in-vitro model and in-vivo patient groups. MATERIALS AND METHODS Radiation dose and image quality were analyzed by varying the filtrat...

متن کامل

Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...

متن کامل

Reduction of patient motion artifacts in digital subtraction angiography: evaluation of a fast and fully automatic technique.

The performance of an automatic technique for the reduction of patient motion artifacts in digital subtraction angiography was evaluated. Four observers assessed the quality of 104 cerebral digital subtraction angiographic images that were processed by means of both the automatic technique and manual pixel shifting. The automatic technique resulted in better image quality and was considerably l...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography.

For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002