Reconstruction of a Radiation Point Source’s Radial Location Using Goodness-of-Fit Test on Spectra Obtained from an HPGe Detector

نویسنده

  • L. T. Evans
چکیده

High purity germanium (HPGe) detectors are ubiquitous in nuclear physics experiments and are also used in numerous low radioactive background detectors. The effect of the position of Co and Cs point sources on the shape of spectra were studied with Monte Carlo and HPGe detector measurements. We briefly confirm previous work on the position dependence of relative heights of peaks. Spectra taken with the radiation sources placed at locations around the detector were then compared using the Kolmogorov-Smirnov (K-S) goodness-of-fit test. We demonstrate that with this method the Compton continuum spectral shape has good sensitivity to the radial location of a point-source, but poor angular resolution. We conclude with a study of the position reconstruction accuracy as a function of the number of counts from the source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction of Co Radiation Source Locations Using Goodness-of-Fit Tests on Spectra Obtained from an HPGe Detector

High purity germanium (HPGe) detectors are ubiquitous in nuclear physics experiments and are also used in numerous low radioactive background detectors, including the proposed Majorana experiment. Spatial reconstruction of the location of radiation sources from spectral distortions could be used to locate unwanted backgrounds or “hot-spots” inside the detector shield. The effect of the position...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

تعیین لایه مرده‎ و بازده قله تمام - انرژی آشکارساز HPGe بااستفاده از کد MCNP و نتایج تجربی

One important factor in using an High Purity Germanium (HPGe) detector is its efficiency that highly depends on the geometry and absorption factors, so that when the configuration of source-detector geometry is changed, the detector efficiency must be re-measured. The best way of determining the efficiency of a detector is measuring the efficiency of standard sources. But considering the fact t...

متن کامل

Collimator-detector response compensation in molecular SPECT reconstruction using STIR framework

Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT.  In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...

متن کامل

ارزیابی مکان آشکارساز نقطه‌ای مجازی در آشکارساز HPGe تخت برای محدوده انرژی k‏eV661-13با استفاده از چشمه‌های فیلتر کاغذی

One of the most important instruments in gamma ray spectroscopy is HPGe detector. Concept of virtual point detector was considered for Ge(Li) detector. On the basis of this concept, there is a point inside a Ge detector that can be regarded as a fictitious point detector hosting all the interactions. If there is really a point whose response can be considered similar to that of the whole real b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009