The 'fixed performance' venturi: effect of downstream pressure on outflow and FIO2.

نویسنده

  • J G Jones
چکیده

Fixed performance venturi devices should provide a predetermined oxygen concentration at an outflow which exceeds an adult's peak resting inspiratory flow rate (approximately 30 l.min(-1)). Campbell's original description mentioned the sensitivity of the venturi device to downstream resistance but gave no further details. This study examined outflow and oxygen concentration from the five standard venturi devices (24-60% O(2)) when downstream pressure increased. Outflow was exquisitely sensitive to small increases in pressure. The outflow at zero downstream pressure for the 24-40% O(2) venturi devices ranged from 40 to 50 l.min(-1) but only 2-3 mmH(2)O was needed to halve this flow and increase oxygen concentration. The 60% O(2) venturi delivered a maximum of only 30 l.min(-1) at zero downstream pressure and flow was reduced further by increasing this pressure. An increase in downstream pressure of only a few mmH(2)O increased oxygen concentration and decreased outflow of all the venturi devices tested, in most to less than normal peak tidal flow in adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance and Emission Characteristics of Dual Fuel Engines at Part Loads Using Simultaneous Effect of Exhaust Gas Recirculation and Pre-Heating of In-let Air

In this study, a numerical simulation using the CFD software, FLUENT, has been conducted to examine the effect of various shapes of the venturi component sections in order to find the optimum venturi specifications to increase the EGR rate with minimum pressure loss at the part load operation range. The CFD results reveal that the venturi should be precisely optimized to introduce the required ...

متن کامل

An Experimental Investigation of Diesel Engines Fuel Injection Pressure Effect on Power Performance and Fuel Consumption

The objective of this paper is to investigate the effect of fuel injection pressure on power performance and fuel consumption of diesel engine. In a diesel engine, fuel injection pressure is an important aspect of the engines’ power performance in order to obtain combustion treatment. The experiments in this paper are performed on a four-cylinder two-stroke direct injection diesel engine. The d...

متن کامل

Variability of inspired oxygen concentration with nasal cannulas.

BACKGROUND The likely values of inspired oxygen concentration (FIO2) of patients with chronic obstructive pulmonary disease breathing via nasal cannulas have not been assessed previously. METHODS Seven patients with chronic obstructive lung disease and seven healthy subjects were studied while breathing oxygen via nasal cannulas or fixed performance (Venturi) or uncontrolled (MC) oxygen masks...

متن کامل

Effect of a ring type barrier and rotational speed on leakage flow of gas turbine brush seal

This paper investigates the effect of inserting a ring type barrier on leakage flow of brush seals with different bristles clearances (the distance between bristle pack tip and rotor surface). The ring is placed on both upstream and downstream sides of the bristles. An axisymmetric CFD model is employed to calculate radial pressure distribution along backing plate, axial pressure variation on r...

متن کامل

Use of venturi entrainment to deliver nasal high flow oxygen.indd

Objective: To evaluate the use of an adjustable venturi device with standard wall oxygen supply to deliver nasal high flow oxygen. Design: We set up a circuit using a standard 15 L/ min oxygen rotameter connected to a wall outlet, 2 m standard oxygen tubing, an adjustable venturi device, humidification chamber and nasal high flow circuit and cannulae. Delivered FiO2 and total gas flow rates wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anaesthesia

دوره 59 7  شماره 

صفحات  -

تاریخ انتشار 2004