Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET.

نویسندگان

  • Rene Nkoulou
  • Tobias A Fuchs
  • Aju P Pazhenkottil
  • Silke M Kuest
  • Jelena R Ghadri
  • Julia Stehli
  • Michael Fiechter
  • Bernhard A Herzog
  • Oliver Gaemperli
  • Ronny R Buechel
  • Philipp A Kaufmann
چکیده

Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. METHODS Absolute MBF was assessed in 28 consecutive patients undergoing adenosine stress-rest myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin CZT SPECT and 13N-ammonia PET, and MFR was calculated as a ratio of hyperemic over resting MBF. Results from both MPI methods were compared, and correlation coefficients were calculated. The diagnostic accuracy of CZT MFRi to predict an abnormal MFR defined as PET MFR less than 2 was assessed using a receiver-operator-characteristic curve. RESULTS Median MBF at rest was comparable between CZT and PET (0.89 [interquartile range (IQR), 0.77-1.00] vs. 0.92 [IQR, 0.78-1.06] mL/g/min; P = not significant) whereas it was significantly lower at stress in CZT than PET (1.11 [IQR, 1.00-1.26] vs. 2.06 [IQR, 1.48-2.56] mL/g/min; P < 0.001). This resulted in median MFRi values of 1.32 (IQR, 1.13-1.52) by CZT and 2.36 (IQR, 1.57-2.71) by PET (P < 0.001). The receiver-operator-characteristic curve revealed a cutoff for CZT MFRi at 1.26 to predict an abnormal PET MFR yielding an accuracy of 75%. CONCLUSION The estimation of absolute MBF index values by CZT SPECT MPI with 99mTc-tetrofosmin is technically feasible, although hyperemic values are significantly lower than from PET with 13N-ammonia, resulting in a substantial underestimation of MFR. Nevertheless, CZT MFRi may confer diagnostic value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements.

UNLABELLED Quantification of myocardial perfusion reserve (MPR) is an emerging topic in nuclear cardiology with an expected diagnostic and prognostic incremental value, especially for patients with severe coronary artery disease. The advent of new dedicated solid-state cameras has opened new perspectives for perfusion quantitation in SPECT. We appraised the feasibility of perfusion reserve esti...

متن کامل

Single-scan rest/stress imaging with 99mTc-Sestamibi and cadmium zinc telluride-based SPECT for hyperemic flow quantification: A feasibility study evaluated with cardiac magnetic resonance imaging

INTRODUCTION We aimed to evaluate whether the hyperemic myocardial blood flow (MBF) can be estimated using cadmium zinc telluride (CZT)-based single-photon emission computed tomography (SPECT) cameras with a single, rapid rest/stress dynamic scan. Dynamic contrast-enhanced (DCE) cardiac magnetic resonance imaging (MRI) was used as a reference modality for flow measurement. MATERIALS AND METHO...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia.

UNLABELLED To validate routine, noninvasive determination of absolute myocardial perfusion and coronary flow reserve (CFR), cardiac PET was performed in animals using a simplified imaging protocol, high-dose dipyridamole and a simplified quantitative algorithm specific for 82Rb and 13N-ammonia. METHODS One hundred thirty-five PET scans were obtained in eight dogs after intravenous 13N-ammonia...

متن کامل

Assessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.

BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 12  شماره 

صفحات  -

تاریخ انتشار 2016