Simultaneous delivery of two patent arterial duct coils via one venous sheath.
نویسندگان
چکیده
A female child, 10 months of age, weighing 7.2 kg, was catheterised for closure of a patent arterial duct. Aortography was performed in the lateral projection and the minimum diameter of the arterial duct was assessed by comparing it to the size of the catheter. The duct size was estimated between 3 and 3.5 mm at the narrowest point, therefore, it was decided to deliver two 5 mm patent arterial duct coils to avoid placement of an 8 mm coil in this small child. Similar operations were subsequently performed in two further children. Simultaneous delivery of two coils via a single long venous sheath is easy, fast, and safe. This simple and inexpensive procedure can reduce irradiation and anaesthesia time.
منابع مشابه
duct coils via one venous sheath . Simultaneous delivery of two patent arterial
Accepted for publication 28 May 1997 Abstract A female child, 10 months of age, weighing 7*2 kg, was catheterised for closure ofa patent arterial duct. Aortography was performed in the lateral projection and the minimum diameter of the arterial duct was assessed by comparing it to the size of the catheter. The duct size was estimated between 3 and 3 5 mm at the narrowest point, therefore, it wa...
متن کاملEfficacy and complications of oral ibuprofen and intravenous acetaminophen in closure of patent ductus arteriosus of preterm neonates
Background: Previous studies have considered patent ductus arteriosus (PDA) a common finding in premature infants, leading to complications such as intracranial hemorrhage, necrotizing enterocolitis and pulmonary dysplasia. The aim of this study was to assess and compare the efficacy of oral ibuprofen and intravenous acetaminophen in the closure of arterial duct in premature newborns. We also e...
متن کاملEarly implantation of multiple spring coils for severe haemolysis after incomplete transcatheter occlusion of persistent arterial duct.
An 18 month old girl with an angiographically measured ductus of 4.5 mm underwent transcatheter occlusion of the persistent arterial duct with a 17 mm Rashkind umbrella and an occluding spring coil. Severe intravascular haemolysis developed 20 hours later. Significant residual ductal leakage was noted and the residual duct measured 6 mm. Previous underestimation might have been related to ducta...
متن کاملLung perfusion studies after detachable coil occlusion of persistent arterial duct.
OBJECTIVE To evaluate relative lung perfusion following complete occlusion of persistent arterial duct with detachable Cook coils. METHODS Ductal occlusion using detachable coils was performed in 35 patients (median age 3.9 years, range 0.5 to 16; 32 native ducts, three patients with previous devices). If the duct could be crossed with a 0.035 inch guidewire and a 4 F catheter after coil impl...
متن کاملDoes change in serum cholesterol of a population influence coronary heart disease mortality?
[1] Shim D, Fedderly RT, Beekman III RH, Ludomirsky A, Young ML, Schork MA, Lloyd TR. Follow-up of coil occlusion of patent ductus arteriosus. J Am Coll Cardiol 1996; 28. 207-11. [2] Galal O, de Moor M, Fadley F et al. Problems encountered during introduction of Gianturco coils for transcatheter occlusion of the patent arterial duct. Eur Heart J 1997; 18: 625-30. [3] Sommer RJ, Gutierrez A, Lai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 78 2 شماره
صفحات -
تاریخ انتشار 1997