Tungsten coil atomizer atomic absorption spectrometry (TCAAS) was used to determine Dy and Eu in acid-digested faeces of sheep. These elements were used as markers in animal nutrition studies. Samples were dried, ground and decomposed using a nitric-perchloric acid mixture. The accuracy of the developed method was evaluated by graphite furnace atomic absorption spectrometry (GFAAS). The results obtained for Eu were validated at a 95% confidence level using a paired t-test. The results for Dy were not validated owing to memory effects caused by carbide formation into the graphite tube. This effect did not occur for Eu. The detection limits for Dy and Eu were 6.9 and 2.1 mug l(-1) by TCAAS, and 2.2 and 5.2 mug l(-1) by GFAAS, respectively. Relative standard deviations (R.S.D.; n=5) were 0.7-3.8 and 0.8-5.6% for Dy and Eu by TCAAS and 0.8-5.4 and 0.3-3.8% for Dy and Eu by GFAAS, respectively. The lifetime of the tungsten coil was around 200 heating cycles, which is three-fold higher than graphite tube lifetime. The proposed method can be used to determine the passage rate of feed through animal digestive tract.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tungsten coil devices in atomic spectrometry: absorption, fluorescence, and emission.

In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) usi...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

Determination of trace elements in aqua regia and nitric acid digests

This Horizontal Standard includes principles and procedures for the determination of trace metals in aqua regia and nitric acid digests of sludge, soil and treated biowaste and neighbouring samples, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable for determination of low concentrations of the following elements: Ag, Cd, Co, Cr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2001