Design and evaluation of an anti-evaporative cover for use with liquid containers.

نویسندگان

  • C A Burtis
  • J S Watson
چکیده

We have designed an anti-evaporative cover for use with the sample and reagent cups and other liquid containers that are required in automated analytical systems. This cover, which is simple in design, consists of a baseplate and a cylindrical chimney. By increasing the height and decreasing the inner diameter of the chimney, evaporative losses can be reduced to less than 0.1%/h; thus, aliquots of sample and reagents can be allowed to remain in their cups and containers for several hours before an analytical error due to evaporation will be measurable. We have also modified a model that we previously developed and validated to estimate evaporative losses from open sample cups, to allow us to predict evaporative losses from cups and containers fitted with the new type of cover. This model confirms that the magnitude of the evaporative loss is inversely proportional to the resistance provided by the headspace above the sample in the cup and by the space defined by the chimney of the cover. With chimney heights ranging from 12 to 36 mm and their inner diameters from 1 to 4 mm, greater than 70% of the resistance to evaporation is provided by the cover.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and construction of evaporative local cooling coatings and evaluate their efficiency in improving some perceptual indicators in laboratory conditions

Introduction: One way to reduce the level of heat strain is to use personal evaporative cooling coats. such as the wrist, ankle, head and neck. The purpose of this study is to design, construct, and determine the cooling power of local cooling coatings and evaluate their efficiency in improving perceptual indicators in the laboratory. Materials and Methods: Initially, the design and constructio...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

A boundary element study for evaluation of the effects of the rigid baffles on liquid sloshing in rigid containers

In this paper, the sloshing response of liquid in a two dimensional rigid rectangular tank with rigid baffles is investigated using boundary element technique. A baffle is a supplementary structural element which supplies a kind of passive control on the effects of ground shaking. The complicated liquid domain is divided into two simple sub-domains so that the liquid velocity potential in each ...

متن کامل

Detection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography

Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 1992