Continuous mechanical chest compression during in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity.
نویسندگان
چکیده
UNLABELLED Survival after in-hospital pulseless electrical activity (PEA) cardiac arrest is poor and has not changed during the last 10 years. Effective chest compressions may improve survival after PEA. We investigated whether a mechanical device (LUCAS™-CPR) can ensure chest compressions during cardiac arrest according to guidelines and without interruption during transport, diagnostic procedures and in the catheter laboratory. METHODS We studied mechanical chest compression in 28 patients with PEA (pulmonary embolism (PE) n=14; cardiogenic shock/acute myocardial infarction; n=9; severe hyperkalemia; n=2; sustained ventricular arrhythmias/electrical storm; n=3) in a university hospital setting. RESULTS During or immediately after CPR, 21 patients underwent coronary angiography and or pulmonary angiography. Successful return of a spontaneous circulation (ROSC) was achieved in 27 out of the 28 patients. Ten patients died within the first hour and three patients died within 24h after CPR. A total of 14 patients survived and were discharged from hospital (13 without significant neurological deficit). Interestingly, six patients with PE did not have thrombolytic therapy due to contraindications. CT-angiography findings in these patients showed fragmentation of the thrombus suggesting thrombus breakdown as an additional effect of mechanical chest compressions. No patients exhibited any life-threatening device-related complications. CONCLUSION Continuous chest compression with an automatic mechanical device is feasible, safe, and might improve outcomes after in-hospital-resuscitation of PEA. Patients with PE may benefit from effective continuous chest compression, probably due to thrombus fragmentation and increased pulmonary artery blood flow.
منابع مشابه
Automated continuous chest compression for in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity: a report of five cases.
Of patients with in-hospital cardiac arrest, those with pulseless electrical activity (PEA) have the worst outcome. Especially in these patients effective chest compressions according to the guidelines may be the key strategy to improve survival. Recently, a novel automatic mechanical chest compression device (LUCAS-CPR) has been shown to ensure effective continuous compressions without interru...
متن کاملInterposed abdominal compression-cardiopulmonary resuscitation after cardiac surgery.
OBJECTIVES The management of cardiac arrest after cardiac surgery differs from the management of cardiac arrest under other circumstances. In other studies, interposed abdominal compression-cardiopulmonary resuscitation (IAC-CPR) resulted in a better outcome compared with conventional CPR. The aim of the present study was to determine the feasibility, safety and efficacy of IAC-CPR compared wit...
متن کاملCardiopulmonary resuscitation for bradycardia with poor perfusion versus pulseless cardiac arrest.
OBJECTIVE The objective of this study was to assess whether pediatric inpatients who receive cardiopulmonary resuscitation (CPR) for bradycardia with poor perfusion are more likely to survive to hospital discharge than pediatric inpatients who receive CPR for pulseless arrest (asystole/pulseless electrical activity [PEA]), after controlling for confounding characteristics. METHODS A prospecti...
متن کاملA Study of Cerebral Performance Categories Based on Initial Rhythm and Resuscitation Time Following In-Hospital Cardiac Arrest in a State Hospital in Turkey
Background: The cerebral performance category (CPC) score is widely used in research and quality assurance to assess neurologic outcome following cardiac arrest. However, little is known about the results of the CPC in Turkey. Objective: This study aimed to determine whether the CPC is associated with the initial rhythm and resuscitation time following re...
متن کاملComparison of the Effects of Three Different Counting Methods on Cardiopulmonary Resuscitation Quality and Rescuer Fatigue
Background: Chest compression with adequate depth and number is one of the main indicators of high-quality cardiopulmonary resuscitation (CPR). Nevertheless, no proper counting technique is suggested to provide sufficient number of massages. Aim: To compare the effects of three techniques of chest compression counting on the quality of CPR and rescuer fatigue. Method: Inthis clinical trial, 30 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Resuscitation
دوره 82 2 شماره
صفحات -
تاریخ انتشار 2011