Ceramic-on-ceramic total hip arthroplasty: incidence and risk factors of bearing surface-related noises in 125 patients.
نویسندگان
چکیده
The ceramic-on-ceramic bearing surface has high wear resistance and good biocompatibility in total hip arthroplasty (THA). However, the postoperative noise problem has been an important issue. The purpose of this retrospective study was to determine the incidence and risk factors of bearing surface-related noises in patients with third-generation ceramic-on-ceramic THAs. One hundred twenty-five patients (143 hips) with ceramic-on-ceramic THAs were included in the study and followed to obtain noise and functional results. Patient factors, including sex, age, height, weight, body mass index, diagnosis, and postoperative range of motion, and surgical factors, including cup inclination, ceramic head size and length, and size of cup related to noises, were recorded. Mean follow-up was 4.2 years (range, 2-10 years). Mean Harris Hip Score was 94 points (range, 68-100 points) at latest follow-up. One (0.8%) patient had radiological evidence of osteolysis, and 4 (3.2%) patients had hip dislocation. No hip sustained a fracture of the ceramic component. Eight (6.4%) patients developed noise at their hips, including clicking in 4, grinding in 2, and snapping in 2. No patient developed squeaking hips or underwent revision surgery because of noisy hips. Younger patients (P=.01), a diagnosis of osteonecrosis (P=.014), a 28-mm ceramic head (P=.042), and a higher hip range of motion postoperatively (P=.001) were related to noise in ceramic-on-ceramic THAs. The study showed third-generation ceramic-on-ceramic THAs had a low incidence of noise problems. However, long-term follow-up is necessary to determine the clinical relevance.
منابع مشابه
Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملHigh survivorship with a titanium-encased alumina ceramic bearing for total hip arthroplasty.
BACKGROUND Although ceramic-on-ceramic bearings for total hip arthroplasty (THA) show promising results in terms of bearing-surface wear, fracture of the bearing, insertional chips, and squeaking remain a concern. QUESTIONS/PURPOSES Our primary objective of this report was to determine overall survivorship of a titanium-encased ceramic-on-ceramic bearing couple. Our secondary objectives were ...
متن کاملThe Epidemiology of Total Hip Arthroplasty Bearing Surface Use in the United States
Introduction: Metal on conventional ultra-high molecular weight polyethylene (UHMWPE) bearings have produced excellent long-term results in total hip arthroplasty (THA), with 20 year survivorship of almost 80%. However, the consequences of bearing surface wear, including osteolysis and aseptic loosening, have been a leading cause of late revision THA, especially in younger, more active patients...
متن کاملMeta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients
PURPOSE The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramic-on-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. MATERIALS AND METHODS We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and ri...
متن کاملTwo- to 9-year clinical results of alumina ceramic-on-ceramic THA.
From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173 patients using alumina ceramic-on-ceramic bearings as part of a prospective United States Food and Drug Administration/Investigational Device Exemption study. The average patient age at surgery was 49.9 years. Minimum followup time was 2 years (mean 4.3 years, range 2-9 years). We evaluated survival rate, implant- and ...