Executive Summary: 2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung.
نویسندگان
چکیده
This document summarises an update to the European Respiratory Society (ERS)/American Thoracic Society (ATS) technical standards for single-breath carbon monoxide uptake in the lung that was last updated in 2005. The full standards are also available online as https://doi.org/10.1183/13993003.00016-2016 The major changes in these technical standards relate to DLCO measurement with systems using rapidly responding gas analysers for carbon monoxide and the tracer gas, which are now the most common type of DLCO instrumentation being manufactured. Technical improvements and the increased capability afforded by these new systems permit enhanced measurement of DLCO and the opportunity to include other optional measures of lung function.
منابع مشابه
2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung.
This document provides an update to the European Respiratory Society (ERS)/American Thoracic Society (ATS) technical standards for single-breath carbon monoxide uptake in the lung that was last updated in 2005. Although both DLCO (diffusing capacity) and TLCO (transfer factor) are valid terms to describe the uptake of carbon monoxide in the lung, the term DLCO is used in this document. A joint ...
متن کامل[Coming together: the ATS/ERS consensus on clinical pulmonary function testing].
S ince 1979, guidelines for standardising pulmonary function tests have been published and updated by both the American Thoracic Society (ATS) [1–6] and the European Respiratory Society (ERS) [7–9]. In addition, several joint ATS/ERS workshops on pulmonary function testing have been held and the resulting reports published [10, 11]. In 1995, European scientists participated in the ATS updates o...
متن کاملSingle-breath transfer factor in young healthy adults: 21% or 17.5% inspired oxygen?
For the measurement of the single-breath transfer factor of the lung for carbon monoxide (TL,CO,sb), the American Thoracic Society (ATS) recommends using a test gas with a 21% inspired fraction of oxygen (FI,O2) whereas the European Respiratory Society (ERS) expressly recommends 17-18% FI,O2. The ERS committee argues that with a higher concentration (e.g. 21%) the alveolar fraction of oxygen (a...
متن کاملPrediction equations for single breath diffusing capacity (Tlco) in a middle aged caucasian population.
BACKGROUND There are many reference equations for the measurement of single breath carbon monoxide diffusing capacity of the lung (Tlco). However, the testing methodologies vary and there are no well documented studies that have developed reference equations for Tlco and alveolar volume (Va) in middle aged and older populations. AIMS (1) Develop reference equations for Tlco in a middle aged p...
متن کاملDLCO: adjust for lung volume, standardised reporting and interpretation
The American Thoracic Society (ATS) and European Respiratory Society (ERS) should be congratulated on updating standards for diffusing capacity of the lung for carbon monoxide (DLCO) [1]. I agree that “Besides varying with age, sex, height and possible ethnicity, DLCO also changes with Hb, lung volume, COHb, PIO2 ..., exercise and body position.” and that “adjustments for these factors be made ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 49 1 شماره
صفحات -