A Lamp Life Predictor for Frequently Switched Instant-start Fluorescent Systems

نویسندگان

  • N. Narendran
  • T. Yin
  • C. O’Rourke
  • A. Bierman
چکیده

ABSTRACT Although T8 fluorescent lamp life is typically rated at 20,000 hours, it can significantly vary depending on the ballast product. The current industry practice for testing fluorescent lamp life requires these lamps to be subjected to 3-hours on/20-minutes off cycle, which is also known as the standard cycle for life testing. This method requires over 2 years of testing, which is expensive and also delays the development of new products. Therefore, researchers have been trying to expedite the procedure for lamp life testing by increasing the switching frequency. However, none of these attempts have shown much promise for correlating the lamp life on faster cycles to the lamp life on the standard cycle. Alternatively, researchers have been trying to correlate certain starting and operating electrical parameters of the lamp-ballast system to lamp life. As an example, it has been shown that the ratio of the hot cathode resistance to cold cathode resistance correlates well with lamp life for rapid-start ballast fluorescent systems. Instant-start ballasts comprise a larger market share than rapid-start ballast. A literature survey shows that at the present time there is no such parameter available for predicting lamp life of instant-start systems. It is also shown in literature that within a range, lamp life shortens with increasing switching frequency. At very fast switching frequencies such as the 5-minutes on/5-minutes off cycle, the major portion of the electrode damage takes place due to starting, which ultimately leads to lamp failure. At standard operating cycles, the electrode damage takes place during starting and operating periods. To predict lamp life on any switching cycle, one has to know the amount of electrode damage that takes place due to starting and the amount of electrode damage that take place due to normal operation. This study deals only with starting effects. The goal of this initial study is to analyze the starting electrical properties and identify a parameter that correlates well to high-frequency switching life, which provides insight to the amount of electrode damage that takes place during starting. It is shown here that the time integrated value of the lamp voltage over the starting

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Study of a Flash-lamp Pumped Passively Q-Switched Nd:YAG Laser Using Cr4+:YAG Saturable Absorber

This paper deals with the experimental results of a xenon flash-lamp pumped passively Q-switched Nd:YAG laser using Cr4+:YAG saturable absorber. The need of a laser cavity to be integrated into a time-of-flight laser range finder is of great interest as an experimental investigation of several laser resonators. Two types of laser resonator, with different lengths, have been studied: the flat-fl...

متن کامل

مقایسه دو روش LAMP فلورسنت و PCR در تشخیص مولکولی سالمونلا

Background and purpose: Salmonella is a group of Enterobacterias that cause infectious diseases in human and animals. Typhoid, bacteremia, enterocolitis and salmonellosis which are caused by this bacterium are considered major health concerns in developing countries, such as Iran. Quick, accurate, reliable and early diagnosis is vital to prevent Salmonella outbreak. Materials and methods: Ther...

متن کامل

The effect of compact fluorescent lamp and curcumin on wound healing in Wistar Rats

Background: Nowadays, the rapid recovery of skin lesions and functional return are among the goals of researchers. The skin is the first defensive barrier against microorganisms in the body and its failure causes infection to spread in all systems of the body. By taking into account the contradictory results of previous studies on the impact of phototherapy on wound healing and also the conside...

متن کامل

Development of a rapid, one-step-visual method to detect Salmonella based on IC-LAMP method

Background: Salmonella can cause serious human gastroenteritis and is frequently isolated from various food samples. The cell culturing, immunoassay, and polymerase chain reactions (PCR) are the current methods to detect such pathogenic agents. However, these methods are time-consuming and labor-intensive, and thus unavailable for rapid-monitoring of Salmonella</em...

متن کامل

A new approach based on state conversion to stability analysis and control design of switched nonlinear cascade systems

In this paper, the problems of control and stabilization of switched nonlinear cascade systems is investigated. The so called simultaneous domination limitation (SDL) is introduced in previous works to assure the existence of a common quadratic Lyapunov function (CQLF) for switched nonlinear cascade systems. According to this idea, if all subsystems of a switched system satisfy the SDL, a CQLF ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000