Optimization of variable temporal averaging in digital fluoroscopy.

نویسندگان

  • C J Kotre
  • E Guibelalde
چکیده

In modern X-ray fluoroscopy systems, the amount of temporal averaging (i.e. persistence) applied to the image is often user selectable. The objective of this work is to quantify the effect of variable temporal averaging on the detection of low contrast test objects moving at a range of known speeds within the digital fluoroscopic image. An image intensifier system with a short-persistence television camera was used to record image sequences of a moving threshold contrast-detail diameter test object onto broadcast-standard U-matic videotape. The image sequences were replayed through an image processing system allowing different amounts of temporal averaging to be applied. The test images were scored by an experienced observer. The temporal averaging time constants produced by the added image processing were measured using a method based on noise correlation. Results are presented showing the trends of threshold contrast with test detail diameter and movement speed. The optimum value of temporal averaging time constant is presented as a function of detail diameter for a range of speeds. By comparison with the limited information available in the literature on organ movement, it is tentatively concluded that for the organ movement speeds expected in the abdomen, the optimum imaging system persistence time constant should be approximately 0.15 s. For the much greater speeds associated with cardiac motion no additional frame averaging, i.e. just the persistence provided by the observer's visual system, appears to be optimal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of Noise Performance in Digital Receivers by Over Sampling the Received Signal

In wireless channel the noise has a zero mean. This channel property can be used in the enhancement of the noise performance in the digital receivers by oversampling the received signal and calculating the decision variable based on the time average of more than one sample of the received signal. The averaging process will reduce the effect of the noise in the decision variable that will approa...

متن کامل

استفاده از POD در استخراج ساختارهای متجانس‌ یک میدان آشفته آماری- همگن

Capability of the Proper Orthogonal Decomposition (POD) method in extraction of the coherent structures from a spatio-temporal chaotic field is assessed in this paper. As the chaotic field, an ensemble of 40 snapshots, obtained from Direct Numerical Simulation (DNS) of the Kuramoto-Sivashinsky (KS) equation, has been used. Contrary to the usual methods, where the ergodicity of the field is need...

متن کامل

Adaptive Weighted Averaging for Real-time MR Imaging

Magnetic resonance imaging (MRI) still suffers from a low signal-to-noise ratio (SNR), especially for real-time imaging sequences. In order to increase the SNR of a sequence of images, an adapted weighted averaging (AWA) approach is proposed and applied to coronary angiography imaging. It can in principle be used for any sequence of 2D images, e.g. fMRI or 3D data sets as well as in CT for fluo...

متن کامل

THE FULL AVERAGING OF FUZZY DIFFERENTIAL INCLUSIONS

In this paper the substantiation of the method of full averaging for fuzzy differential inclusions is considered. These results generalize the results of [17, 20] for differential inclusions with Hukuhara derivative and of [18] for fuzzy differential equations.

متن کامل

Sociological Impact of Using Digital (Web-based) Analyses on Performance Measurement and Optimization of Digital Marketing among Young Managers (Case study: Digital-based Companies in Tehran)

This research aims to study the effect of using digital (web-based) analyses in performance measurement and optimization of digital marketing in digital-based companies in Tehran. The data collection tool was a researcher-made questionnaire. A panel of experts and supervisor were asked to measure the validity of the questionnaire. For reliability analysis of this tool, Cronbach’s alpha test was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 77 920  شماره 

صفحات  -

تاریخ انتشار 2004