On-line combination of capillary isoelectric focusing and capillary non-gel sieving electrophoresis using a hollow-fiber membrane interface: a novel two-dimensional separation system for proteins.

نویسندگان

  • Hechun Liu
  • Chun Yang
  • Qing Yang
  • Weibing Zhang
  • Yukui Zhang
چکیده

A novel two-dimensional (2D) separation system for proteins was reported. In the system, a piece of dialysis hollow-fiber membrane was employed as the interface for on-line combination of capillary isoelectric focusing (CIEF) and capillary non-gel sieving electrophoresis (CNGSE). The system is similar equivalent to two-dimensional polyacrylamide gel electrophoresis (2D PAGE), by transferring the principal of 2D PAGE separation to the capillary format. Proteins were focused and separated in first dimension CIEF based on their differences in isoelectric points (pIs). Focused protein zones was transferred to the dialysis hollow-fiber interface, where proteins hydrophobically complexed with sodium dodecyl sulfate (SDS). The negatively charged proteins were electromigrated and further resolved by their differences in size in the second dimension CNGSE, in which dextran solution, a replaceable sieving matrix instead of cross-linked polyacrylamide gel was employed for size-dependent separation of proteins. The combination of the two techniques was attributed to high efficiency of the dialysis membrane interface. The feasibility and the orthogonality of the combined CIEF-CNGSE separation technique, an important factor for maximizing peak capacity or resolution elements, were demonstrated by examining each technique independently for the separation of hemoglobin and protein mixtures excreting from lung cancer cells of rat. The 2D separation strategy was found to greatly increase the resolving power and overall peak capacity over those obtained for either dimension alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of non-gel-based two-dimensional separation of intact proteins by an on-line hyphenation of capillary isoelectric focusing and hollow fiber flow field-flow fractionation.

A rapid, non-gel-based, on-line, two-dimensional separation method is introduced for proteome analysis. Protein fractionation was carried out by first exploiting the differences in their respective isoelectric points (pI) in a Teflon capillary using isoelectric focusing (IEF), followed by a molecular weight (MW)-based separation in a hollow fiber by flow field-flow fractionation (FlFFF). The me...

متن کامل

Two−dimensional separation of human plasma proteins using agarose gel isoelectric focusing followed by SDS capillary electrophoresis

Two−dimensional polyacryiamide gel electrophoresis (2−D PAGE) has been widely used for protein separation because of its high resolution; more than one thousand proteins or polypeptides can be separated according to the differences of their isoelectric point (pI) and molecular mass. However, 2−D PAGE involves many steps of manual handling, sample injection, setting gel molds in an electrophores...

متن کامل

Capillary electrophoresis as a second dimension to isoelectric focusing for peptide separation.

Capillary zone electrophoresis and carrier ampholytes based capillary electrophoresis have been used as a second separation step to Off-Gel isoelectric focusing for the analysis of complex peptide mixtures. A tryptic digest of four proteins (bovine serum albumin, beta-lactoglobulin, horse myoglobin, cytochrome c) has been chosen as a peptide test mixture. After assessment of different modes of ...

متن کامل

Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.

CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo...

متن کامل

Whole-Column-Imaging Detection for Capillary Isoelectric Focusing and Capillary Electrophoresis

Despite the significant advantages of capillary isoelectric focusing over gel isoelectric focusing, widespread acceptance of the technique as a replacement for gel isoelectric focusing has not occurred. Several factors contribute to capillary isoelectric focusing’s slower-than-expected adoption; perhaps the most important are the performance and procedural difficulties introduced when capillary...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 817 1  شماره 

صفحات  -

تاریخ انتشار 2005