Artificial cornea: towards a synthetic onlay for correction of refractive error.

نویسندگان

  • R Z Xie
  • S Stretton
  • D F Sweeney
چکیده

Synthetic onlays that are implanted onto the surface of the cornea have the potential to become an alternative to spectacles and contact lenses for the correction of refractive error. A successful corneal onlay is dependent on development of a biocompatible polymer material that will maintain a healthy cornea after implantation and that will promote growth of corneal epithelial cells over the onlay, and development of a method for attachment of the onlay with minimal surgical invasiveness. The ideal onlay should be made of a material that is highly permeable yet has sufficient surface characteristics to stimulate stable and firm attachment of the corneal epithelium over the onlay. Recent research indicates that collagen I coated polymer materials that mimic the basement membrane of the corneal epithelium promote the most favorable growth of epithelial cells in vivo in comparison to wholly biological or synthetic materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Progress in the development of a synthetic corneal onlay.

PURPOSE This study evaluated an improved perfluoropolyether polymer formulation designed for use as a corneal onlay to correct refractive error. METHODS Collagen I coated perfluoropolyether lenticules were implanted in feline corneas exposing a 6-mm diameter area of lenticule surface for epithelial growth. A parallel series of sham-wounded corneas were also studied. All corneas were monitored...

متن کامل

بررسی اصلاح قوز قرنیه با استفاده از قطعات ‏حلقوی داخل قرنیه‌ای فرارا

  Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years).   Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacl...

متن کامل

Standardized analyses of correction of astigmatism by laser systems that reshape the cornea.

PURPOSE To develop a minimum set of analyses and a format for presentation of outcomes of astigmatism correction by laser systems that reshape the cornea. METHODS An Astigmatism Project group was created under the auspices of the American National Standards Institute (ANSI) Z80.11 Working Group on Laser Systems for Corneal Reshaping. The Astigmatism Project Group was made up of experts in ast...

متن کامل

Long-Term Efficacy of Photorefractive Keratectomy In Hyperopia Patients

Hyperopia is a common refractive error that is usually corrected with eyeglasses or contact lenses. Following the fast advancement in refractive surgery and technology, eyeglasses or contact lenses were no longer the single treatment option in refractive errors. Today, extraction of transparent lens and intraocular lens implantation, phacic intraocular lens applications and corneal surgeries ar...

متن کامل

Corneal shape and eccentricity in population.

The human cornea is an important tissue involved in the mediation of visual perception. It is important to measure its shape especially in the case of correction of refractive errors. Suitable correction such as contact lenses is chosen based on the measured values of the refractive error. An inappropriately fitted contact lens can significantly affect the physiology of the cornea and the eye. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioscience reports

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2001