OBJECTIVE The purpose of this study was to assess the safety of sonographically guided percutaneous finger and thumb first annular (A1) pulley releases performed using needle and hook knife techniques in an unembalmed cadaveric model. METHODS A single operator completed 50 (40 fingers and 10 thumbs) sonographically guided percutaneous A1 pulley releases in unembalmed cadavers using previously described needle and hook knife techniques and simulated local anesthesia. Half of the fingers and thumbs were completed with each technique. An experienced observer blinded to the technique dissected each specimen and assessed for neurovascular, flexor tendon, and A2 pulley injury. Completeness of release was also recorded as a secondary outcome. RESULTS No neurovascular or A2 pulley injury occurred in any digit, regardless of technique. No significant flexor tendon injury was seen in any digit, although minor surface scratches were visualized in 3 cases (6%; 2 knife and 1 needle). The hook knife technique was significantly more likely to result in a complete pulley release compared to the needle technique (22 of 25 [88%] versus 8 of 25 [32%]; P < .001). CONCLUSIONS Sonographically guided percutaneous A1 pulley releases can be performed safely using previously described needle and hook knife techniques. The safety margin for thumb releases is less than that for finger releases, particularly with respect to the radial digital nerve. These cadaveric data support recently published clinical investigations recommending consideration of sonographically guided percutaneous A1 pulley release in the management of patients with a disabling trigger finger.
منابع مشابه
Commentary: Percutaneous release of the A1 pulley using a modified Kirschner wire: a cadaveric study.
PURPOSE. To evaluate the outcome of percutaneous release of the A1 pulley in 40 cadaveric fingers using a modified Kirschner wire. METHODS. A 2.5-mm-diameter Kirschner wire measuring >12 cm in length was used. One end of the wire was sharpened into a 'J' shape using a grinder. The J-shaped tip featured a blunt, elongated lower tip, a sharp J-shaped curve, and a blunt upper tip. Completeness of ...
متن کاملPercutaneous release of the A1 pulley: a cadaver study.
PURPOSE Percutaneous release of the A1 pulley has been used for treatment of trigger fingers with success. However, lack of direct visualization raises concerns about the completeness of the release and about potential injury to the tendons or neurovascular structures. The purpose of this study was to assess the efficacy and safety of percutaneous release of the A1 pulley in a cadaveric model u...
متن کاملAssessment of the Distal Extent of the A1 Pulley Release: A New Technique
OBJECTIVE Sharp division of the A1 pulley is a time-honored technique for the treatment of flexor tendon entrapment; however, this procedure is not without complications. The anatomy of the A1 pulley system has been carefully investigated. Knowledge of superficial anatomic landmarks can assist with demarcating the distal edge of the A1 pulley and prevent damage to the critical A2 pulley. METH...
متن کاملThe results of percutaneous release of trigger digits by using full handle knife 15 degrees: an anatomical hand surface landmark and clinical study.
OBJECTIVE Know the results of percutaneous release of trigger digits by using full handle knife 15 degrees. MATERIAL AND METHOD The author identified 510 cadaveric digits to find the anatomical landmark of Al pulley that relates to the knuckle and measurements of A1 pulley lengths. The proximal margin of the Al pulleys on the perpendicular line from the knuckle to the palm was in the same lin...
متن کاملThe percutaneous trigger finger release scalpel - the A knife
Open A1 pulley release is a standard surgical procedure for treatment of trigger finger. The disadvantages of the open technique include injury to the soft tissue, developing a painful palmar scar and patients requiring an extended recovery timethesince the procedure is more complex. Another technique used for treatment of trigger finger is percutaneous release. This technique offers the benefi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 29 11 شماره
صفحات -
تاریخ انتشار 2010