Perception of Interaural Phase Differences With Envelope and Fine Structure Coding Strategies in Bilateral Cochlear Implant Users

نویسندگان

  • Stefan Zirn
  • Susan Arndt
  • Antje Aschendorff
  • Roland Laszig
  • Thomas Wesarg
چکیده

The ability to detect a target signal masked by noise is improved in normal-hearing listeners when interaural phase differences (IPDs) between the ear signals exist either in the masker or in the signal. To improve binaural hearing in bilaterally implanted cochlear implant (BiCI) users, a coding strategy providing the best possible access to IPD is highly desirable. In this study, we compared two coding strategies in BiCI users provided with CI systems from MED-EL (Innsbruck, Austria). The CI systems were bilaterally programmed either with the fine structure processing strategy FS4 or with the constant rate strategy high definition continuous interleaved sampling (HDCIS). Familiarization periods between 6 and 12 weeks were considered. The effect of IPD was measured in two types of experiments: (a) IPD detection thresholds with tonal signals addressing mainly one apical interaural electrode pair and (b) with speech in noise in terms of binaural speech intelligibility level differences (BILD) addressing multiple electrodes bilaterally. The results in (a) showed improved IPD detection thresholds with FS4 compared with HDCIS in four out of the seven BiCI users. In contrast, 12 BiCI users in (b) showed similar BILD with FS4 (0.6 ± 1.9 dB) and HDCIS (0.5 ± 2.0 dB). However, no correlation between results in (a) and (b) both obtained with FS4 was found. In conclusion, the degree of IPD sensitivity determined on an apical interaural electrode pair was not an indicator for BILD based on bilateral multielectrode stimulation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of interaural time differences in fine structure and en

Objectives: Bilateral cochlear implant (CI) listeners currently use stimulation strategies which encode interaural time differences (ITD) in the temporal envelope but which do not transmit ITD in the fine structure, due to the constant phase in the electrical pulse train. To determine the utility of encoding ITD in the fine structure, ITD-based lateralization was investigated with four CI liste...

متن کامل

Lateralization of Sounds Based on Interaural Time Differences in Cochlear Implant Listeners

Interaural time differences (ITD) occur when a binaural signal is delayed at one ear. They arise when a sound is presented outside of the median plane of a subject. In modulated sounds like speech, ITD is present in both the rapidly varying fine structure and the slowly varying envelope. There is evidence that ITD in the fine structure of a sound is most important for sound localization and for...

متن کامل

Effects of interaural time differences in fine structure and envelope on lateral discrimination in electric hearing.

Bilateral cochlear implant (CI) listeners currently use stimulation strategies which encode interaural time differences (ITD) in the temporal envelope but which do not transmit ITD in the fine structure, due to the constant phase in the electric pulse train. To determine the utility of encoding ITD in the fine structure, ITD-based lateralization was investigated with four CI listeners and four ...

متن کامل

Title: Sensitivity of Inferior Colliculus Neurons to Interaural Time Differences in the Envelope versus the Fine Structure with Bilateral Cochlear Implants

Bilateral cochlear implantation seeks to improve hearing by taking advantage of the binaural processing of the central auditory system. Cochlear implants typically encode sound in each spectral channel by amplitude modulating (AM) a fixed-rate pulse train, thus interaural time differences (ITD) are only delivered in the envelope. We investigated the ITD sensitivity of inferior colliculus (IC) n...

متن کامل

The Effect of Interaural Frequency Mismatch on Correlation Change Detection in Bilateral Cochlear-Implant Users

The Effect of Interaural Frequency Mismatch on Correlation Change Detection in Bilateral Cochlear-Implant Users Matthew Goupell University of Maryland College Park Background The insertion depth of a cochlear implant (CI) may differ across the ears in the case of bilateral implantation. This will cause an interaural frequency mismatch of electrical stimulation that may affect binaural processin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016