Quantitation of size of relative myocardial perfusion defect by single-photon emission computed tomography.

نویسندگان

  • J H Caldwell
  • D L Williams
  • G D Harp
  • J R Stratton
  • J L Ritchie
چکیده

The purpose of this study was to validate a semiautomatic method for quantitating the size of relative myocardial perfusion defects from single-photon emission computed tomographic (SPECT) images. We compared the size of the image defect in vivo, expressed as percent of involved left ventricle, as determined by this method with the anatomic size of the defect in vitro in 19 dogs. To test the method under optimal conditions, we first labeled the left ventricular myocardium in nine dogs by left atrial injection of 99mTc-labeled macroaggregated albumin particles after acute occlusion of one coronary artery. The "defect volume" was defined as the volume of the left ventricular myocardium for which counts fell 2 or more SDs below the distribution of counts in the myocardium supplied by a normal coronary artery in a series of animals. The relative in vivo defect volume by SPECT occupied 26.46 +/- 12.7% of the left ventricular volume (mean +/- SD), compared with a relative defect size in vitro of 33.3 +/- 13.7% (p = NS) of left ventricular volume as determined by well counting of myocardial samples. There was a close correlation between the two measurements (r = .92). However, myocardial relative defect volumes involving less than 5% of myocardium were not identified by SPECT. The defect volume weighted for the relative reduction in flow within the defect zone or the relative "reduced perfusion volume" was also determined. The correlation between the estimates by SPECT and those made in vitro for relative reduced perfusion volume was also high (r = .94).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

LABORATORY INVESTIGATION SINGLE-PHOTON EMISSION TOMOGRAPHY Quantitation of size of relative myocardial perfusion defect by single-photon emission computed tomography

The purpose of this study was to validate a semiautomatic method for quantitating the size of relative myocardial perfusion defects from single-photon emission computed tomographic (SPECT) images. We compared the size of the image defect in vivo, expressed as percent of involved left ventricle, as determined by this method with the anatomic size of the defect in vitro in 19 dogs. To test the me...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

Phase II Safety and Clinical Comparison With Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease

Objectives This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) ( 50% stenosis) on in...

متن کامل

The quantification of infarct size.

We sought to summarize the published evidence regarding the measurement of infarct size by serum markers, technetium-99m sestamibi single-photon emission computed tomography (SPECT) myocardial perfusion imaging, and magnetic resonance imaging. The measurement of infarct size is an attractive surrogate end point for the early assessment of new therapies for acute myocardial infarction. For each ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 70 6  شماره 

صفحات  -

تاریخ انتشار 1984