Light-switching excimer probes for rapid protein monitoring in complex biological fluids.

نویسندگان

  • Chaoyong James Yang
  • Steffen Jockusch
  • Marie Vicens
  • Nicholas J Turro
  • Weihong Tan
چکیده

Quantitative protein bioanalysis in complex biological fluids presents considerable challenges in biological studies and disease diagnosis. The major obstacles are the background signals from both the probe and the biological fluids where the proteins reside. We have molecularly engineered light-switching excimer aptamer probes for rapid and sensitive detection of a biomarker protein, platelet-derived growth factor (PDGF). Labeled with one pyrene at each end, the aptamer switches its fluorescence emission from approximately 400 nm (pyrene monomer) to 485 nm (pyrene excimer) upon PDGF binding. This fluorescence wavelength change from monomer to excimer emission is a result of aptamer conformation rearrangement induced by target binding. The excimer probe is able to effectively detect picomolar PDGF in homogeneous solutions. Because the excimer has a much longer fluorescence lifetime (approximately 40 ns) than that of the background (approximately 5 ns), time-resolved measurements were used to eliminate the biological background. We thus were able to detect PDGF in a cell sample quantitatively without any sample pretreatment. This molecular engineering strategy can be used to develop other aptamer probes for protein monitoring. Combined with lifetime-based measurements and molecular engineering, light-switching excimer aptamer probes hold great potential in protein analysis for biomedical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A general excimer signaling approach for aptamer sensors.

Simple, fast and direct analysis or monitoring of significant molecules in complex biological samples is important for many biological study, clinical diagnosis and forensic investigations. Herein we highlight a general method to tailor aptamer sequence into functional subunits to design target-induced light-switching excimer sensors for rapid, sensitive and selective detection of important mol...

متن کامل

[DNA duplex-based fluorescence probes/sensors using monomer-excimer switching].

In this review, we report DNA duplex-based fluorescence probes/sensors using pyrene monomer-excimer switching. The review mainly comprises two topics: 1) excimer-monomer switching molecular beacons (EMS-MB) and 2) monomer-excimer switching sensors based on the structural motif of antibodies. The EMS-MBs have two pyrene fluorophores connected both at 3' and 5' ends of a single-stranded oligonucl...

متن کامل

Comparison of the oxygen sensor performance of some pyrene derivatives in silicone polymer matrix

Pyrene and its derivatives find application as fluorescent probes for monitoring the oxygen concentrations in air and various fluids. Photophysical characteristics of some commercially available derivatives of pyrene in silicone polymer matrix were studied in order to find out whether they could be employed as a substitute for pyrene in the pressure sensitive paint (PSP). The derivatives under ...

متن کامل

Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid

Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 102 48  شماره 

صفحات  -

تاریخ انتشار 2005