Comparison of Manual, Femtosecond Laser, and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver Eyes.

نویسندگان

  • Vance M Thompson
  • John P Berdahl
  • Joel M Solano
  • David F Chang
چکیده

PURPOSE To compare the anterior lens capsulotomy edge tear strength created by manual continuous curvilinear capsulorhexis (CCC), femtosecond laser capsulotomy (FSLC), and a new automated precision pulse capsulotomy (PPC) device. DESIGN A 3-arm study in paired human cadaver eyes. PARTICIPANTS A total of 44 eye specimens from 22 donors in the United States. METHODS Capsulotomy was performed in all eye specimens using manual CCC, a femtosecond laser (LenSx, Alcon, Fort Worth, TX), or an automated PPC device (Zepto, Mynosys Inc., Fremont, CA). The first study arm consisted of 8 pairs of eyes in which 1 eye received PPC and the fellow eye received FSLC. The second study arm consisted of 8 pairs of eyes, with 1 eye receiving PPC and the fellow eye receiving manual CCC. The third study arm consisted of 6 pairs of eyes, with 1 eye receiving a manual CCC and the fellow eye receiving FSLC. After phacoemulsification, 2 capsulotomy edge retractors attached to force transducers were used to stretch the capsulotomy edge of each eye and to measure the resisting force until the capsulotomy edge was torn. MAIN OUTCOME MEASURES Capsulotomy edge tear strength in millinewtons. RESULTS The PPC edge tear strength was greater than that of FSLC for all 8 pairs of eyes by an average factor of 3.1-fold (PPC mean 73.3±24.9 mN vs. femtosecond laser mean 26.1±6.8 mN; P = 0.012, Wilcoxon matched-pairs, signed-ranks test). The PPC tear strength was greater than that of manual CCC for all 8 pairs of eyes by an average factor of 4.1-fold (PPC mean 95±35.2 mN vs. manual CCC mean 29.1±23.1 mN; P = 0.012, Wilcoxon matched-pairs signed-ranks test). There was no significant difference in the tear strength of capsulotomies produced by manual CCC (mean 21.3±4.9 mN) and FSLC (mean 24.5±11.4 mN) (P = 0.75, Wilcoxon matched-pairs signed-ranks test). CONCLUSIONS The strength of the PPC capsulotomy edge was significantly stronger than that produced by femtosecond laser or manual CCC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femtosecond laser capsulotomy.

PURPOSE To evaluate a femtosecond laser system to create the capsulotomy. SETTING Porcine and cadaver eye studies were performed at OptiMedica Corp., Santa Clara, California, USA; the human trial was performed at the Centro Laser, Santo Domingo, Dominican Republic. DESIGN Experimental and clinical study. METHODS Capsulotomies performed by an optical coherence tomography-guided femtosecond...

متن کامل

Precision Pulse Capsulotomy

Purpose: To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Design: Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Participants: Human cadaver eyes and New Zealand white rabbits. Methods: Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy d...

متن کامل

Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery.

PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...

متن کامل

Light microscopy and scanning electron microscopy analysis of rigid curved interface femtosecond laser-assisted and manual anterior capsulotomy.

PURPOSE To study the microanatomic edge structures of anterior lens capsule specimens derived from manual and femtosecond laser-assisted capsulotomies. SETTING Department of Ophthalmology, Goethe-University, Frankfurt, Germany. DESIGN Experimental study. METHODS Of 60 eyes with lens removal and intraocular lens implantation, 30 received a manual capsulotomy and 30 received a femtosecond l...

متن کامل

Analysis of Femtosecond Laser Assisted Capsulotomy Cutting Edges and Manual Capsulorhexis Using Environmental Scanning Electron Microscopy

Purpose. To investigate the structure and irregularity of the capsulotomy cutting edges created by two femtosecond (FS) laser platforms in comparison with manual continuous circular capsulorhexis (CCC) using environmental scanning electron microscopy (eSEM). Methods. Ten anterior capsulotomies were obtained using two different FS laser cataract platforms (LenSx, n = 5, and Victus, n = 5). In ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 123 2  شماره 

صفحات  -

تاریخ انتشار 2016