Highly sensitive immunoradiometric assay for serum thyroglobulin with minimal interference from autoantibodies.

نویسندگان

  • P Y Marquet
  • A Daver
  • R Sapin
  • B Bridgi
  • J P Muratet
  • D J Hartmann
  • F Paolucci
  • B Pau
چکیده

Five monoclonal antibodies (MAbs) directed against antigenic domains on thyroglobulin (Tg) not recognized by most anti-Tg human autoantibodies (aAbs) have been used to develop an improved IRMA for serum Tg with a limit of detection of 0.2 micrograms/L. Samples are incubated for 3 h in tubes coated with four anti-Tg MAbs. After washing, the tubes are incubated with the tracer MAb for 20 h at room temperature. Dilution and reproducibility tests demonstrated assay reliability. Tests performed on samples with (n = 361) or without (n = 283) aAbs showed that the TG IRMA Pasteur is largely independent of the marked interference generally caused by aAbs. These results were confirmed with an extended population of 2759 samples. For a cutoff of 1 micrograms/L, sensitivity and specificity were 0.97 and 1, respectively, in a follow-up of differentiated thyroid carcinoma in patients treated by total thyroidectomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonisotopic "sandwich" immunoassay of thyroglobulin in serum by the biotin-streptavidin technique: evaluation and comparison with an immunoradiometric assay.

In this sequential assay, the thyroglobulin in serum binds to polystyrene beads coated with two mouse monoclonal antibodies. These beads then react with a rabbit polyclonal antibody, biotinylated sheep anti-rabbit IgG, streptavidin-horseradish peroxidase, and a peroxidase substrate to yield a colored product that is measured spectrophotometrically at 492 nm. The range of the standard curve is 1...

متن کامل

Current status and performance goals for serum thyroglobulin assays.

Serum thyroglobulin (Tg) measurements are used as a tumor marker for monitoring patients with differentiated thyroid carcinoma. The clinical utility of six different Tg methods [RIA or immunometric assay (IMA)] currently used in Europe and the US was evaluated, with focus on methodologic standardization, sensitivity, interassay precision across the typical clinical monitoring interval (6 to 12 ...

متن کامل

Differences in radioimmunoassay results for thyroglobulin that affect management of patients with thyroid cancer.

We compared two commercial assays for measurement of serum thyroglobulin [Nuclear Medical Systems (NMS) and "CIS" (Damon Diagnostics)] with each other and with one developed at Stanford (J Clin Endocrinol Metab 49:557-564, 1979). The NMS assay is a competitive-binding RIA, the CIS and Stanford assays are two-site immunoradiometric assays. The kit standards varied in thyroglobulin concentration....

متن کامل

ELISA for thyroglobulin in serum: recovery studies to evaluate autoantibody interference and reliability of thyroglobulin values.

An ELISA for measuring thyroglobulin (Tg) in serum was developed with polyclonal antibodies to Tg on the solid phase and two monoclonal antibodies to Tg as the second antibodies. The assay has a detection limit of 1 microgram/L, a within-run imprecision (CV) of <7%, and a between-run CV of < 10%. Parallelism of the assay was shown in dilution studies, in which the percent observed/expected valu...

متن کامل

Highly sensitive assays of autoantibodies to thyroglobulin and to thyroid peroxidase.

These highly sensitive assays are based on the interaction between thyroid autoantibodies and 125I-labeled autoantigens. Serum samples are incubated with labeled thyroid peroxidase (TPO) or thyroglobulin (Tg) to allow the formation of antibody-labeled antigen complexes. The complexes are then precipitated by addition of solid-phase Protein A. In the presence of high concentrations of TPO antibo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 1996