Impact of Quenching Failure of Cy Dyes in Differential Gel Electrophoresis

نویسندگان

  • Weiqun Wang
  • Doreen Ackermann
  • Anna-Maria Mehlich
  • Simone König
چکیده

BACKGROUND Differential gel electrophoresis (DIGE) is a technology widely used for protein expression analysis. It is based on labelling with fluorescent Cy dyes. In comparative fluorescence gel electrophoresis experiments, however, unspecific labelling using N-hydroxy-succinimide-ester-based labelling protocols was recently detected. Cross-talk was observed due to failure of the quenching process. Here, the impact of this effect for DIGE experiments was investigated. METHODOLOGY/PRINCIPAL FINDINGS Experiments to test quenching efficiency were performed in replicate using Escherichia coli lysate. Parameters such as the amount of dye and quencher were varied. Labelling and quenching were reversed in one experiment. Differences in protein spot volumes due to limited quenching were determined. For some spots twice the volume was detected underscoring the importance of proper control of silencing of active dye. CONCLUSIONS/SIGNIFICANCE It could be demonstrated that uncontrolled labelling increased protein spot volume, even doubling it in some cases. Moreover, proteins responded differently to the protocol. Such unpredictable and unspecific processes are not acceptable in protein regulation studies so that it is necessary to validate the correct amount of quencher for individual samples before the DIGE experiment is performed. Increase of the concentration of lysine, which is used as quencher, from 10 mM to 2500 mM, was sufficient to silence the dye. Alternatively, active dye molecules can be removed by filtration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proteomic analysis of redox- and ErbB2-dependent changes in mammary luminal epithelial cells using cysteine- and lysine-labelling two-dimensional difference gel electrophoresis.

Differential protein expression analysis based on modification of selected amino acids with labelling reagents has become the major method of choice for quantitative proteomics. One such methodology, two-dimensional difference gel electrophoresis (2-D DIGE), uses a matched set of fluorescent N-hydroxysuccinimidyl (NHS) ester cyanine dyes to label lysine residues in different samples which can b...

متن کامل

Selective Labelling of Cell-surface Proteins using CyDye DIGE Fluor Minimal Dyes

Surface proteins are central to the cell's ability to react to its environment and to interact with neighboring cells. They are known to be inducers of almost all intracellular signaling. Moreover, they play an important role in environmental adaptation and drug treatment, and are often involved in disease pathogenesis and pathology (1). Protein-protein interactions are intrinsic to signaling p...

متن کامل

Practical syntheses of dyes for difference gel electrophoresis.

The three dyes (two indocyanine and one benzoxazolium) useful in difference gel electrophoresis-methyl Cy5 1, propyl Cy3 2, and the benzoxazolium dye Cy2 3--and their NHS esters have been prepared by efficient routes in good overall yield from inexpensive precursors.

متن کامل

A gel-based proteomic comparison of human cerebrospinal fluid between inflicted and non-inflicted pediatric traumatic brain injury.

Traumatic brain injury (TBI) is the most common cause of traumatic death in infancy, and inflicted TBI (iTBI) is the predominant cause. Like other central nervous system pathologies, TBI changes the composition of cerebrospinal fluid (CSF), which may represent a unique clinical window on brain pathophysiology. Proteomic analysis, including two-dimensional (2-D) difference in gel electrophoresis...

متن کامل

Determining a significant change in protein expression with DeCyder during a pair-wise comparison using two-dimensional difference gel electrophoresis.

Two-dimensional difference gel electrophoresis (DIGE) is a tool for measuring changes in protein expression between samples involving pre-electrophoretic labeling with cyanine dyes. Here we assess a common method to analyze DIGE data using the DeCyder software system. Experimental error was studied by a series of same sample comparisons. Aliquots of sample were labeled with N-hydroxyl succinimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011