Hypoxia imaging with 18F-FAZA PET/CT predicts radiotherapy response in esophageal adenocarcinoma xenografts

نویسندگان

  • Elodie Melsens
  • Elly De Vlieghere
  • Benedicte Descamps
  • Christian Vanhove
  • Ken Kersemans
  • Filip De Vos
  • Ingeborg Goethals
  • Boudewijn Brans
  • Olivier De Wever
  • Wim Ceelen
  • Piet Pattyn
چکیده

BACKGROUND Esophageal cancer is an aggressive disease with poor survival rates. A more patient-tailored approach based on predictive biomarkers could improve outcome. We aimed to predict radiotherapy (RT) response by imaging tumor hypoxia with 18F-FAZA PET/CT in an esophageal adenocarcinoma (EAC) mouse model. Additionally, we investigated the radiosensitizing effect of the hypoxia modifier nimorazole in vitro and in vivo. METHODS In vitro MTS cell proliferation assays (OACM5 1.C SC1, human EAC cell line) were performed under normoxic and hypoxic (< 1%) conditions: control (100 μL PBS), nimorazole, irradiation (5, 10 or 20 Gy) with or without nimorazole. In vivo, subcutaneous xenografts were induced in nude mice (OACM5 1.C SC1). Treatment was given daily for 5 consecutive days: (A) control (600 μl NaCl 0.9% intraperitoneally (IP)) (N = 5, n = 7), (B) RT (5 Gy/d) (N = 11, n = 20), (C) combination (nimorazole (200 mg/kg/d IP) 30 min before RT) (N = 13, n = 21). N = number of mice, n = number of tumors. 18F-FAZA PET/CT was performed before treatment and tumor to background (T/B) ratios were calculated. Relative tumor growth was calculated and tumor sections were examined histologically (hypoxia, proliferation). RESULTS A T/B ≥ 3.59 on pre-treatment 18F-FAZA PET/CT was predictive for worse RT response (sensitivity 92.3%, specificity 71.4%). Radiation was less effective in hypoxic tumors (T/B ≥ 3.59) compared to normoxic tumors (T/B < 3.59) (P = 0.0025). In vitro, pre-treatment with nimorazole significantly decreased hypoxic radioresistance (P < 0.01) while in vivo, nimorazole enhanced the efficacy of RT to suppress cancer cell proliferation in hypoxic tumor areas (Ki67, P = 0.064), but did not affect macroscopic tumor growth. CONCLUSIONS Tumor tissue hypoxia as measured with 18F-FAZA PET/CT is predictive for RT response in an EAC xenograft model. The radiosensitizing effect of nimorazole was questionable and requires further investigation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamics of tumor hypoxia assessed by 18F-FAZA PET/CT in head and neck and lung cancer patients during chemoradiation: possible implications for radiotherapy treatment planning strategies.

INTRODUCTION To define the optimal time point for the integration of hypoxia (18)F-FAZA-PET/CT information into radiotherapy treatment planning to benefit from hypoxia modification or dose escalation treatment. Therefore, we performed a prospective cohort study, using serial hypoxic imaging ((18)F-FAZA-PET/CT) prior to and at several time-points during (chemo)radiotherapy (CHRT) in six head and...

متن کامل

Hypoxia imaging with the nitroimidazole 18F-FAZA PET tracer: a comparison with OxyLite, EPR oximetry and 19F-MRI relaxometry.

BACKGROUND AND PURPOSE (18)F-FAZA is a nitroimidazole PET tracer that can provide images of tumor hypoxia. However, it cannot provide absolute pO(2) values. To qualify (18)F-FAZA PET, we compared PET images to pO(2) measured by OxyLite, EPR oximetry and (19)F-MRI. MATERIALS AND METHODS Male WAG/Rij rats grafted with rhabdomyosarcoma were used. Tumor oxygenation was modified by gas breathing (...

متن کامل

18F-FAZA PET imaging response tracks the reoxygenation of tumors in mice upon treatment with the mitochondrial complex I inhibitor BAY 87-2243.

PURPOSE We describe a noninvasive PET imaging method that monitors early therapeutic efficacy of BAY 87-2243, a novel small-molecule inhibitor of mitochondrial complex I as a function of hypoxia-inducible factor-1α (HIF1α) activity. EXPERIMENTAL DESIGN Four PET tracers [(18)F-FDG, (18)F-Fpp(RGD)2, (18)F-FLT, and (18)F-FAZA] were assessed for uptake into tumor xenografts of drug-responsive (H4...

متن کامل

Personalized Medicine and Imaging F-FAZA PET Imaging Response Tracks the Reoxygenation of Tumors in Mice upon Treatment with the Mitochondrial Complex I Inhibitor

Purpose:We describe a noninvasive PET imaging method that monitors early therapeutic efficacy of BAY 87-2243, a novel smallmolecule inhibitor of mitochondrial complex I as a function of hypoxia-inducible factor-1a (HIF1a) activity. Experimental Design: Four PET tracers [F-FDG, F-Fpp (RGD)2, F-FLT, and F-FAZA] were assessed for uptake into tumor xenografts of drug-responsive (H460, PC3) or drug-...

متن کامل

Significant impact of different oxygen breathing conditions on noninvasive in vivo tumor-hypoxia imaging using [18F]-fluoro-azomycinarabino-furanoside ([18F]FAZA)

BACKGROUND [18F]FAZA is a PET biomarker with great potential for imaging tumor hypoxia. Aim of our study was to compare [18F]FAZA uptake in mice with subcutaneous exogenous CT26 colon carcinomas and endogenous polyoma middle-T (PyV-mT) mammary carcinomas and to analyze the influence of different breathing protocols in CT26 colon carcinomas as well as the reversibility or irreversibility of [18F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018