Brachytherapy dose‐volume histogram commissioning with multiple planning systems
نویسندگان
چکیده
The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA testing was positioned coplanar and concentric with one end. Using the brachytherapy dosimetry formalism defined in the AAPM Task Group 43 report series, calculations were performed to estimate dose deposition in partial volumes of the cuboid structure. The point-source approximation was used for a 125I source and the line-source approximation was used for a 192Ir source in simulated permanent and temporary implants, respectively. Hand-calculated, dose-volume results were compared to TPS-generated, dose-volume histogram (DVH) data to ascertain acceptance. The average disagreement observed between hand calculations and the treatment planning system DVH was less than 1% for the five treatment planning systems and less than 5% for 1 cm ≤ r ≤ 5 cm. A reproducible method for verifying the accuracy of volumetric statistics from a radiation therapy TPS can be employed. The process satisfies QA requirements for TPS commissioning, upgrading, and annual testing. We suggest that investigations be performed if the DVH %Vol(TPS) "actual variance" calculations differ by more than 5% at any specific radial distance with respect to %Vol(TG-43), or if the "average variance" DVH %Vol(TPS) calculations differ by more than 2% over all radial distances with respect to %Vol(TG-43).
منابع مشابه
Addendum to brachytherapy dose‐volume histogram commissioning with multiple planning systems
The process for validating dose-volume histogram data in brachytherapy software is presented as a supplement to a previously published article. Included is the DVH accuracy evaluation of the Best NOMOS treatment planning system called "Best TPS VolumePlan." As done previously in other software, a rectangular cuboid was contoured in the treatment planning system. A single radioactive 125I source...
متن کاملQuality assurance procedures during commissioning of a treatment planning system as a tool to establish new standards before migration
PURPOSE Treatment planning system commissioning is one of the most important parts of the quality assurance system in a working brachytherapy department. Migration to a more sophisticated system is always a step forward for the planning team but careful verification of the workflow and obtained results is mandatory. The question is not only whether the quality and safety of the previous standar...
متن کاملThe Role of Computed Tomography Based Treatment Planning in High Dose Rate (hdr) Brachytherapy in Carcinoma of the Cervix
Aim: To compare the high dose rate (HDR) brachytherapy treatment planning using standard orthogonal radiography and computerized tomography (CT) for carcinoma of the cervix. Methods: Forty applications with orthogonal planning using the Brachy Vision treatment planning system version 7.3.10 were performed. Orthogonal and CT based planning in these applications were compared; the doses to point ...
متن کاملDose volume uniformity index: a simple tool for treatment plan evaluation in brachytherapy
PURPOSE In radiotherapy treatment planning, dose homogeneity inside the target volume plays a significant role in the final treatment outcome. Especially in brachytherapy where there is a steep dose gradient in the dose distribution inside the target volume, comparing the plans based on the dose homogeneity helps in assessing the high dose volume inside the final treatment plan. In brachytherap...
متن کاملApplicator volume elimination methods and their influence on DVH analysis of HDR prostate implants
In CT anatomy-based inverse treatment planning of interstitial high-dose rate (HDR) brachytherapy planning, the planning target volume (PTV) delineated by the radiation oncologist includes the applicator volume. The applicator volume can be eliminated with the help of two methods: one based on Boolean operations and the other using the erasing option of the application software. Both methods ar...