Two new types of laser Doppler flowmeters Prototypes validation

نویسنده

  • Edite Figueiras
چکیده

....................................................................................................................................... IX Resumo ......................................................................................................................................... XI Figures list ................................................................................................................................... XV List of tables .............................................................................................................................. XVII Abbreviations ............................................................................................................................. XIX 1Introduction .............................................................................................................................. 1 1.1 Motivation ........................................................................................................................... 1 1.2 Purpose ............................................................................................................................... 2 1.3 Thesis structure ................................................................................................................... 2 2Laser Doppler Flowmetry ......................................................................................................... 3 2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-domain algorithm for single-photon laser-Doppler flowmetry at large interoptode spacing in human bone.

A new laser-Doppler flowmeter at large interoptode spacing, based on single-photon counting (single-photon laser-Doppler flowmetry [SP-LDF]) and allowing assessment of blood flow deep in bone tissue, is proposed and implemented. To exploit the advantages of the new SP-LDF hardware, a dedicated simple and efficient time-domain algorithm has been developed. The new algorithm is based on the zero-...

متن کامل

Bone tissue phantoms for optical flowmeters at large interoptode spacing generated by 3D-stereolithography

A bone tissue phantom prototype allowing to test, in general, optical flowmeters at large interoptode spacings, such as laser-Doppler flowmetry or diffuse correlation spectroscopy, has been developed by 3D-stereolithography technique. It has been demonstrated that complex tissue vascular systems of any geometrical shape can be conceived. Absorption coefficient, reduced scattering coefficient an...

متن کامل

Pre-clinical validation of a new intra-operative "dual beam Doppler" blood flowmeter in an artificial circuit.

BACKGROUND Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinica...

متن کامل

Flowmetry (flow measurement)

Flowmetry. Fluid-flow measurement and visualisation ................................................................................ 1 Measuring mass flow-rate ......................................................................................................................... 2 Accumulative weighting .............................................................................................

متن کامل

Cochlear blood flow increases after systemic hemodilution: comparison of simultaneous laser Doppler flowmetry and radioactive microsphere measurements.

Guinea pig cochlear blood flow was measured before and after systemic normovolemic hemodilution with high molecular weight dextran. Absolute determinations of blood flow (in the cochlea, brain, kidney and lung) were accomplished by use of radioactive-labeled (85Sr or 141Ce) microspheres. Relative measurements of the cochlear blood flow changes were made simultaneously by the use of a laser Dopp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011