A sampling calorimeter with warm-liquid ionization chambers

نویسندگان

  • S. Plewnia
  • Th. Berghöfer
  • J. Blümer
  • P. Buchholz
  • J. Engler
  • N. O. Hashim
  • R. Lixandru
  • J. Milke
  • W. Walkowiak
  • J. Wochele
چکیده

An iron sampling calorimeter with warm-liquid ionization chambers has been tested at the CERN SPS in order to study the signal development and to verify the energy calibration of the hadron calorimeter in the KASCADE-Grande air shower experiment. The absolute energy calibration of the detectors is discussed. Results of the analysis of the lateral and longitudinal shower development in the calorimeter are presented and compared with results from simulations based on the GEANT/FLUKA code. r 2006 Elsevier B.V. All rights reserved. PACS: 29.40.Vj; 95.55.Vj

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of output factors using different ionization chambers and build up caps

Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...

متن کامل

Micromegas for imaging calorimetry

Gaseous detectors have been used in sampling calorimeters for several years and still remain an attractive option for future collider experiments. The use of Micromegas chambers as active elements of a hadronic calorimeter was proposed a few years ago and stirred up exciting developments of this technology. Basic building blocks of large size chambers acting as signal generating and processing ...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

The ATLAS liquid argon hadronic end-cap calorimeter: construction and selected beam test results

ATLAS has chosen for its Hadronic End-Cap Calorimeter (HEC) the copper-liquid argon sampling technique with flat plate geometry and GaAs pre-amplifiers in the argon. The contruction of the calorimeter is now approaching completion. Results of production quality checks are reported and their anticipated impact on calorimeter performance discussed. Selected results, such as linearity, electron an...

متن کامل

High-resolution electro-magnetic calorimetry with noble liquids

Electromagnetic calorimeters with noble liquids and their limits in resolution are discussed. The origins of “initial” current measurement in calorimetry are retraced and the performance and first results of the NA48 calorimeter (quasi-homogeneous calorimeter with longitudinal electrode structure) are presented. Results of the prototype calorimeters of KEDR (quasi-homogeneous calorimeter with t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006