Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays.

نویسندگان

  • Glen H Johnson
  • Lloyd A Mancl
  • E Ricardo Schwedhelm
  • Douglas R Verhoef
  • Xavier Lepe
چکیده

STATEMENT OF PROBLEM Success rates for making fixed prosthodontic impressions based on material and tray selection are not known. PURPOSE The purpose of this clinical study was to compare first impression success rates for 2 types of impression material and 2 impression tray systems. MATERIAL AND METHODS Dual-viscosity impressions were made with a vinyl polysiloxane (VPS) (Aquasil Ultra Monophase/Aquasil Ultra XLV) and a polyether (PE) (Impregum Penta Soft HB/Impregum Garant Soft LB) impression material. The first impression made was evaluated for success or failure using developed criteria. Fifty senior dental students participated. The type of impression material alternated for each new patient. A full-arch perforated plastic (President Tray) or a plastic dual-arch impression tray (Tri-Bite) was used based on clinical guidelines. Impression success rates were compared using logistic regression, fitted using the method of generalized estimating equations (alpha=.05). RESULTS One hundred ninety-one impressions were evaluated, and the overall success rate was 61% for VPS and 54% for PE (P=.39). Additional regression analyses, adjusted for potential confounders, did not indicate a difference between the 2 systems (P=.35). There was little difference in success rates between the 2 materials when a full-arch tray was used (50% versus 49% success, P=.89), whereas a larger difference was apparent with the use of dual-arch trays (70% success with VPS versus 58% success with PE, P=.21). The most common critical defect was located on the preparation finish line (94%), and the most common operator error was inadequate gingival displacement (15%). CONCLUSIONS There was little difference in success rates between VPS and PE when full-arch impression trays were used, but there was greater success when using VPS with dual-arch trays. For single teeth, the trend favored VPS, but when more than one prepared tooth per impression was involved, the success rate was higher for PE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo Study of the Accuracy of Dual-arch Impressions.

BACKGROUND This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. MATERIALS AND METHODS In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a patte...

متن کامل

Distortion of disposable plastic stock trays when used with putty vinyl polysiloxane impression materials.

STATEMENT OF PROBLEM Impressions are made using high-viscosity putty vinyl polysiloxane impression materials in conjunction with disposable plastic stock trays. The impression materials have been shown to be dimensionally stable. However, it remains unclear if the disposable plastic stock trays are rigid enough to resist deformation thus yielding potentially unreliable results. PURPOSE This s...

متن کامل

Accuracy of the second pour casts using dual-arch trays.

OBJECTIVE To compare, in vitro, the accuracy between dental stone casts obtained from the first and the second pour using metallic (Smart) and plastic (Triple Tray) dual-arch trays. MATERIAL AND METHODS The impressions were taken using Flexitime® vinyl polysiloxane from a typodont model with a mandibular right first molar prepared for a full crown. Ten impressions were made with each tray and...

متن کامل

بررسی مقایسه‌ای تری‌های ‌قالب‌گیری تمام قوس و نیم قوس بر دقت ابعادی و زاویه‌ای قالب‌های تهیه‌ شده از ایمپلنت‌های زاویه‌دار

Background and Aims: Taking impression from angulated implants has always been a great challenge in clinic. In this regard, studies on sectional trays are very few. The aim of this study was to evaluate and compare the dimensional and angular accuracy of impressions using full arch and sectional trays. Materials and Methods: Four implants (4.3 × 12 mm) (Implantium, Dentium) were plac...

متن کامل

Effect of variation of impression material combinations, dual arch tray types, and sequence of pour on the accuracy of working dies: “An in vitro study”

AIMS To evaluate the accuracy of dies made from dual arch impressions using different sectional dual arch trays, combinations of elastomeric impression materials, and the sequence of pour of dies. SUBJECTS AND METHODS The dual arch impression materials were grouped into three groups depending on the combination of impression materials used and each group is subdivided into four subgroups. A s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 103 1  شماره 

صفحات  -

تاریخ انتشار 2010