‘‘Smart’’ Base Isolation Strategies Employing Magnetorheological Dampers

نویسندگان

  • H. Yoshioka
  • J. C. Ramallo
چکیده

One of the most successful means of protecting structures against severe seismic events is base isolation. However, optimal design of base isolation systems depends on the magnitude of the design level earthquake that is considered. The features of an isolation system designed for an El Centro-type earthquake typically will not be optimal for a Northridge-type earthquake and vice versa. To be effective during a wide range of seismic events, an isolation system must be adaptable. To demonstrate the efficacy of recently proposed ‘‘smart’’ base isolation paradigms, this paper presents the results of an experimental study of a particular adaptable, or smart, base isolation system that employs magnetorheological ~MR! dampers. The experimental structure, constructed and tested at the Structural Dynamics and Control/Earthquake Engineering Laboratory at the Univ. of Notre Dame, is a base-isolated two-degree-of-freedom building model subjected to simulated ground motion. A sponge-type MR damper is installed between the base and the ground to provide controllable damping for the system. The effectiveness of the proposed smart base isolation system is demonstrated for both far-field and near-field earthquake excitations. DOI: 10.1061/~ASCE!0733-9399~2002!128:5~540! CE Database keywords: Damping; Base isolation; Earthquake excitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

‘‘Smart’’ Base Isolation Systems

A ‘‘smart’’ base isolation strategy is proposed and shown to effectively protect structures against extreme earthquakes without sacrificing performance during the more frequent, moderate seismic events. The proposed smart base isolation system is composed of conventional low-damping elastomeric bearings and ‘‘smart’’ controllable ~semiactive! dampers, such as magnetorheological fluid dampers. T...

متن کامل

Parameter Identication of Large-Scale Magnetorheological Dampers in a Benchmark Building Platform

——Magnetorheological (MR) dampers are devices that can be used for vibration reduction in structures. However, to use these devices in an effective way, a precise modeling is required. In this sense, in this paper we consider a modied parameter identication method of large-scale magnetorheological dampers which are represented using the normalized BoucWen model. The main benet of the propose...

متن کامل

Parameter identification of large-scale magnetorheological dampers in a benchmark building

Magnetorheological (MR) dampers are devices that can be used for vibration reduction in structures. However, to use these devices in an effective way, a precise modeling is required. In this sense, in this paper we consider a modified parameter identification method of large-scale magnetorheological dampers which are represented using the normalized Bouc-Wen model. The main benefit of the propo...

متن کامل

INVESTIGATION OF THE OPTIMAL SEMI-ACTIVE CONTROL STRATEGIES OF ADJACENT BUILDINGS CONNECTED WITH MAGNETORHEOLOGICAL DAMPERS

This study investigates the efficacy of optimal semi-active dampers for achieving the best results in seismic response mitigation of adjacent buildings connected to each other by magnetorheological (MR) dampers under earthquakes. One of the challenges in the application of this study is to develop an effective optimal control strategy that can fully utilize the capabilities of the MR dampers. H...

متن کامل

Smart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems

Sample controllers for a three-dimensional smart base-isolated building benchmark problem with linear and frictional isolation system are presented in this paper. A Kalman filter is used to estimate the states based on absolute acceleration measurements. Input filters are used to better inform the controller of the spectral content of the earthquake excitations. A reduced order control-oriented...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002