Foley catheter action in the nasopharynx: a cadaveric study.
نویسندگان
چکیده
OBJECTIVES To determine the action of the Foley catheter in the posterior nasal cavity in relation to balloon volume, and to deduce its implications in the treatment of posterior epistaxis. DESIGN Human cadaveric study. MATERIALS Twenty nasal fossae of 10 adult cadavers. INTERVENTIONS A Foley catheter (size 14) was inserted into the nasopharynx via each nostril. The catheter balloon was inflated to its recommended maximum volume with 15 mL of water. Firm traction was applied to the catheter. Colored liquid was instilled into the ipsilateral aspect of the nasal cavity, and liquid leakage into the contralateral side was monitored using a nasoendoscope. The balloon was reduced in volume by 1-mL steps, and the same fluid infusion and documentation procedures were performed for each reduced volume until the balloon slipped out of the nose. The procedure was repeated in the opposite nostril. MAIN OUTCOME MEASURES Successful choanal sealing and anterior balloon shift into the nasal fossa in relation to the balloon size. RESULTS The Foley catheter balloon sealed the choana without any leakage of infused liquid into the contralateral side at appropriate inflation volumes in 17 (85%) of 20 nasal fossae. Complete sealing between volumes of 12 and 15 mL was achieved in 13 fossae (65%), between 11 and 15 mL in 10 nasal fossae (50%), and between 5 and 15 mL in 3 nasal fossae (15%). Failure to seal at any volume occurred in 3 nasal fossae (15%). Bimodal seal (ie, complete seal at high [15 mL] and low volumes [4-7 mL], but leakage in intermediate volumes) occurred in 3 nasal fossae (15%). The balloon remained in the nasopharynx under traction and did not slip past the choanal rim to encroach on the middle and inferior turbinates until the balloon volume was reduced to between 4 and 7 mL. The balloon slid out of the nose at a volume of 5 mL or less. The inflation volumes ranging from 8 to 12 mL were statistically more effective in sealing the choana than lower volumes (4-7 mL) (P<.002, chi(2) test). CONCLUSIONS At different inflation volumes, the Foley catheter balloon acts primarily (1) as a platform for an anterior gauze pack (at 4-15 mL); (2) as an effective seal of the choana (at 8-15 mL usually and at 4-7 mL occasionally); and (3) as a compressor of the region behind the middle and inferior turbinates (at 4-7 mL), provided that the balloon under traction does not slip out of the nose.
منابع مشابه
Effect of Foley Catheter in Prepration of Cervix for Delivery
Abstract The aim of this study was comparing the efficacy of induction of labor using balloon Foley catheter with conventional Oxytocin infusion method in cases of unfavorable cervix. 60 pregnant women that had an indication for induction of labor with a singleton vertex fetuses, intact membranes, and bishop score lower than 4 interred in this study and allocated in one of two induction method...
متن کاملComparison of the Efficacy of PGE2 Suppository and Cervical Foley Catheter with Pre-induction Ripening of the Cervix
Background: An increasing success in induction of labor and subsequent termination of pregnancy in presence of unfavorable cervix requires cervical ripening in order to reduce complications and to diminish the rate of cesarean sections as well as the duration of labor. However, there is no consensus on the efficiency of conventional methods for cervical ripening. Objective: To determine and co...
متن کاملIs Foley Catheter Able to Drain the Bladder Completely in the Morning for Patients in ICU?
Introduction: Foley catheters are assumed to drain the bladder completely. It is known that uncompleted drainage leads to multiple complications, such as asymptomatic bacteriuria and urinary tract infection. Methods: From 116 patients, who were admitted to intensive care unit (ICU) for more than 24 hours, were enrolled in this study. To measure the urine level in bladder in the morning before a...
متن کاملComparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
At times, despite an unripe cervix, induction of labor may be needed. In these cases, a safe and suitable method should be considered for cervical ripening and pregnancy termination. The aim of this study is the comparison of vaginal misoprostol with Foley catheter for cervical ripening and induction of labor. This randomized clinical trial was performed on 108 pregnant women who had referred t...
متن کاملINDUCTION OF LABOR WITH USE OF A FOLEY CATHETER AND EXTRAAMNIOTIC CORTICOSTEROIDS
The purpose of this study is to show the effect of extraamniotic administration of corticosteroids to shorten the times to either active labor and/or delivery. This is a double blind randomized study. 65 patients who were candidates for the termination of pregnancy between the ages of 16-45, with intact membranes and unripe cervix were randomly divided into two groups, a study group (n=34)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of otolaryngology--head & neck surgery
دوره 126 9 شماره
صفحات -
تاریخ انتشار 2000