Design parameters of a low flow rate sidestream capnograph.

نویسنده

  • Brian M Fudge
چکیده

The use of sidestream capnometers, with a sampling rate of 150-250 cc/min, as a means of measuring a patient's expired CO2 (ETCO2) and respiratory rate, has been a common practice for many years. However, in recent years, there has been a focus on lower flow rate sampling sidestream systems due to the benefits of less loss of tidal volume for patients, such as infants or neonates. When developing a sidestream system, four principle issues must be considered; 1) The signal fidelity of the gas sample must be sufficiently maintained from the sampling site to the measurement site. 2) Condensate from a patient's breath, as well as blood, mucus, or other contaminates often pose problems for sidestream systems and requires mitigation. 3) The mechanics of transporting a gas sample at a constant flow rate through the sampling system, regardless of atmospheric or clinical conditions must be developed. 4) The physics of handling CO2 gas throughout the transport process must be understood in order to ensure accurate readings. These issues lead to a complex web of interrelations that are explored in the development of a low flow rate sidestream capnometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of nitrous oxide-oxygen inhalation with scavenging on behavioral and physiological parameters during routine pediatric dental treatment.

PURPOSE The purpose of this study was to determine the influence of 40% nitrous oxide/60% oxygen inhalation with scavenging on the behavioral and physiological parameters during routine pediatric dental procedures. METHODS Twenty-two subjects, aged 60-116 months, were randomized into a double blind, cross-over study design and administered alternately either 40% nitrous oxide/60% oxygen or 10...

متن کامل

Effects of breathing parameters on sidestream cigarette smoke deposition in a hollow tracheobronchial model.

The effects of variations in cyclic breathing parameters (i.e., tidal volume and breath frequency) have been the subject of few studies devoted to the deposition of submicrometer aerosols in the human respiratory tract. Therefore, a series of experiments was performed to investigate whether the deposition efficiency (DE) of sidestream cigarette smoke is altered by varying tidal volume and breat...

متن کامل

Design and Implementation of the Rotor Blades of Small Horizontal Axis Wind Turbine

Since the renewable resources of energy have become extremely important, especially wind energy, scientists have begun to modify the design of the wind turbine components, mainly rotor blades. Aerodynamic design considered a major research field related to power production of a small horizontal wind turbine, especially in low wind speed locations. This study displays an approach to the selectio...

متن کامل

Effect of Blade Design Parameters on Air Flow through an Axial Fan

The objective of this paper is the numerical study of the flow through an axial fan and examining the effects of blade design parameters on the performance of the fan. The axial fan is extensively used for cooling of the electronic devices and servers. Simulation of the three-dimensional incompressible turbulent flow was conducted by numerical solution of the (RANS) equations for a model. The S...

متن کامل

The Effect of the Variation of Volume Flow Rate on the Thermal Parameters of a Solar Air Collector with a Single Pass of Air: Case Study for Laghouat, Algeria

The effect of the volume flow rate of the heat transfer fluid (air) on the thermal parameters of the solar air collector with a single air pass without using fins under the absorbing plate have been investigated experimentally and theoretically. We use a new design of solar air collector which aims to optimize these parameters in the region cited above. Our solar air collector was realized at t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical sciences instrumentation

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2005