Polyethylene wear in total hip arthroplasty.
نویسندگان
چکیده
Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined polyethylene cups. Two patient groups were matched individually for gender, age, weight, and length of followup. Analyses were done using the technique of Livermore et al. The bearing surface evaluation consisted of 3 groups after matching, leaving 77 patients per group. Results showed linear wear rates of 0.06 mm per year, 0.05 mm per year, and 0.08 mm per year for stainless steel, cobalt chrome, and titanium alloy, respectively. The comparison between cemented molded metal-backed and nonmetal-backed acetabular components was not matched, with 134 metal-backed and 99 nonmetal-backed components. Results showed linear wear rates of 0.011 mm per year in the metal-backed group and 0.08 mm per year in the nonmetal-backed group. Results were statistically significant. These results indicate that the metal composition of the femoral bearing surface has minimal, if any, effect on the linear polyethylene wear rate. The method of polyethylene fabrication and the use of metal backing had a significant effect on the polyethylene wear rate in these patient groups. These results suggest that the compression-molded all-polyethylene acetabular component may be optimal for reducing polyethylene wear in total hip arthroplasty.
منابع مشابه
Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis
Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...
متن کاملAlumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinic...
متن کاملA comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up
STUDY DESIGN This is a retrospective study comparing polyethylene wear between ceramic ball heads and metal ball heads in total hip arthroplasty. BACKGROUND The ceramic-on-polyethylene bearing option has been introduced as an alternative to metal-on-polyethylene to minimize polyethylene wear debris and reduce subsequent osteolysis and aseptic loosening. However, the reported data were debatab...
متن کاملInfluence of Pelvic Tilt on Polyethylene Wear after Total Hip Arthroplasty
We aimed to evaluate the effects of pelvic tilt on polyethylene wear after total hip arthroplasty (THA). A total of 105 joints treated with primary THA were included; conventional polyethylene (CPE) liners were used in 43 hips and highly cross-linked polyethylene (HXLPE) liners were used in the remaining 62 hips. The pelvis was tilted 6° posteriorly in the standing position as compared to the s...
متن کاملIn Vivo Wear Particles of Annealed Highly Cross-Linked Polyethylene in Total Hip Arthropalsty
INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...
متن کاملIn Vivo Wear Particles of Remelted Highly Cross-Linked Polyethylene in Total Hip Arthropalsty
INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 317 شماره
صفحات -
تاریخ انتشار 1995